User Manual
97
The output power of the
inverter will vary in response to
the grid voltages.
V1 Ref.
207.0V
V2 Ref.
220.0V
V3 Ref.
250.0V
V4 Ref.
265.0V
P1 Ref.
0.0%
P2 Ref.
P3 Ref.
P4 Ref.
100.0%
100.0%
100.0%
Tab. 12-5
“
Volt-Watt (Chrg)
” Mode Parameter Explanations
Parameter
Explanation
Default
Range
AU (WP)
AU
(except
WP)
NZ
V1 Ref.
Grid voltage
reference value 1
205.0 V
207.0 V
207.0 V 190 V–215 V
V2 Ref.
Grid voltage
reference value 2
220.0 V
220.0 V
220.0 V 216 V–230 V
V3 Ref.
Grid voltage
reference value 3
235.0 V
250.0 V
244.0 V 235 V–255 V
V4 Ref.
Grid voltage
reference value 4
250.0 V
265.0 V
255.0 V 244 V–265 V
P1 Ref.
Power
consumption
upper limit 1
0 %
0–100 %
P2 Ref.
Power
consumption
upper limit 2
100 %
P3 Ref.
Power
consumption
upper limit 3
100 %
P4 Ref.
Power
consumption
upper limit 4
100 %
Power
,
P
/P
rated
%
200
Inverter Voltage, V
V2
V3
V4
210
220
230
240
250
260
270
40%
60%
20%
80%
0%
V1
100%
Default characteristic
Range (lower limit)
Range (upper limit)
Fig. 12-4
Vtg-Watt Response Mode for Battery Charging Curve (“AU” for example)