100
13 Appendix IV: Technical Data
13.1
Inverter
PV Input Data
Max. PV input power
6500 W
Max. PV input voltage
600 V
Startup voltage
125 V
Nominal input voltage
350 V
MPP voltage range
125 V–560 V
MPP voltage range for nominal
power
240 V–520 V
No. of MPPTs
2
Max. number of PV strings per
MPPT
(DC1/DC2)
1/1
Max. PV input current (DC1/DC2)
22 A (11 A / 11 A)
Max. current for input terminals
24 A (12 A / 12 A)
Short circuit current of PV input
24 A (12 A / 12 A)
Max. inverter backfeed current to
strings
0 A
Battery Data
Battery type
Li-ion battery / Lead-acid battery
Battery voltage (rated voltage /
range)
48 V (32 V–70 V)
Max. charging / discharging current
65 A / 65 A
AC Input and Output Data
Nominal AC output power to grid
4990 W
Max. AC output apparent power to
grid
5000 VA
Max. AC input power from grid
3000 W
Nominal AC output current
21.6 A
Max. AC output current
21.7 A
Max. inrush current (peak/duration)
10 A / 12 ms
Max. output fault
current
(peak/duration)
100 A / 3.2 ms
Max. output over-current protection
32 A
Nominal grid voltage
230 Vac
Grid voltage range
180 Vac–276 Vac
(this may vary with grid standards)
Nominal grid frequency
50 Hz
Grid frequency range
45 Hz–55 Hz
(this may vary with grid standards)