User Manual
32
Self-tapping screw M6
Spring washer
Fender washer
Expansion tube
1.
Install the wall-mounting bracket with a torque of 9.0 N
m.
Note that the depth of the holes should be about 70 mm. Be sure to
adhere to the screw assembly sequence: self-tapping screw, spring
washer, fender washer and bracket.
240
D10
Mark the positions
Drill holes
Place expansion tubes
Secure the bracket
mm
2.
Mount the inverter to the
bracket.
3.
Secure the inverter with two
M5 screws and washers. (3.0
N
m)