User Manual
41
3.
Align the AC connector
and the AC terminal and
mate them together by
hand until a “Click” is
heard or felt.
4.
Connect the other ends. Connect “PE” conductor to the grounding
electrode. Connect “L” and “N” conductors to the AC circuit breaker.
The PE wire of the AC terminal must be directly connected to the
grounding bar. Do not connect it to protection devices such as the
circuit breaker.
5.
Make sure all AC cables are firmly installed via the right torque tool or
dragging the cables slightly.
6.5 DC Cable Connection
Electric shock!
The PV array will generate lethal high voltage once exposed to
sunlight.
Make sure the PV array is well insulated to ground before connecting it to
the inverter.
6.5.1 PV Input Configuration
Independent Mode
The two PV inputs work independently, each with its own MPPT. The two PV
inputs can be different from each other in PV module types, numbers of PV
panels in PV strings, tilt angles and orientation angles of PV modules. The
following figure details the need for a homogenous PV string structure for
maximum power.