User Manual
102
Backup Data
Nominal voltage
230 Vac (± 2 %)
Total harmonic factor output
2 % (full resistive load)
Frequency range
50 Hz (±0.2 %)
Switch time to emergency mode
3 s
Power factor
0.8 overexcited/leading–0.8
underexcited/lagging
Max. output power
5000 W / 5000 VA
Max. output power (battery mode)
3000 W / 3000 VA
13.2
STB5K-20 (backup box)
Max. EPS power
5000 W
Max. output current for EPS port
25 A
Nominal AC voltage
230 Vac
AC voltage range
180 Vac–276 Vac
Nominal AC frequency
50 Hz
Operating ambient temperature
range
-25
℃
to 60
℃
Power consumption
< 3 VA / 2 W
Dimensions (W x H x D)
220 mm x 230 mm x 90 mm
Mounting method
Wall-mounting bracket
Weight
2.6 kg
13.3
Energy Meter
Item
Single-phase
Three-phase
Nominal voltage
240 Vac
230 Vac / 400
Vac
Input voltage range
180 Vac–286 Vac
180 Vac–276
Vac
Power consumption
< 2 W (10 VA)
< 2 W (10 VA)
Max. operating current
100 A
65 A
Grid frequency
50 Hz
Measurement accuracy
Class I
Interface and communication
RS485
Ingress protection rating
IP20
Operating ambient temperature
-25
℃
to 75
℃
-25
℃
to 70
℃
Relative humidity
0–95 %
Mounting method
35 mm DIN-rail
Dimensions (W x H x D)
18 x 117 x 65 (mm)
85 x 72 x 72
(mm)