44
6
Appendices
6.1
Inverter Technical Data
PV Input Data
Max. PV input power
6500 W
Max. PV input voltage
600 V
Startup voltage
125 V
Nominal input voltage
360 V
MPP voltage range
125 V–560 V
MPP voltage range for nominal power
260 V–520 V
No. of MPPTs
2
Max. number of PV strings per MPPT
(DC1/DC2)
1/1
Max. PV input current (DC1/DC2)
20 A (10 A / 10 A)
Max. current for input terminals
12 A
Short-circuit current of PV input
24 A (12 A / 12 A)
Max. inverter backfeed current to array
0 A
Battery Data
Battery type
Li-ion battery / Lead-acid battery
Battery voltage (rated voltage / range)
48 V (32 V–70 V)
Max. charging/discharging current
65 A / 65 A
AC Input and Output Data
Max. AC input power
3000 W
Nominal AC output power
4990 W
Nominal AC output current
21.6 A
Max. AC output apparent power
5000 VA
Max. AC output current
21.7 A
Max. inrush current (peak value / duration)
10 A / 12 ms
Max. output fault current
(peak value / duration)
100 A / 3.2 ms
Max. output over-current protection
32 A
Nominal grid voltage
230 Vac
Grid voltage range
180 Vac–276 Vac
(this may vary with grid standards)
Nominal grid frequency
50 Hz
Grid frequency range
45 Hz–55 Hz
(this may vary with grid standards)
Total Harmonic Distortion (THD)
< 3 % (of nominal power)
DC current injection
< 0.5 % (of nominal current)
Summary of Contents for SH5K
Page 1: ...SH5K QUEN Ver14 201708 Version 1 4 Quick User Manual SH5K Grid Connected Hybrid Inverter ...
Page 2: ......
Page 4: ...II System Overview ...
Page 5: ...III ...
Page 6: ...IV ...
Page 7: ...V ...
Page 8: ...VI ...
Page 9: ...VII ...
Page 10: ...VIII ...
Page 32: ...3 Commissioning Quick User Manual 20 Fig 3 2 Initial Settings ...