background image

03

Blue LED will be on when the item is in operating 
condition.

Once the unit reaching 7,500hrs of operation, 
orange LED will be on. 

When false operation, red LED will be on. 

02

Power Cable

(SPC-MT-2-001)

<Controller>

Length : 1.8M

D-Sub Cable

(SDC-SN-4-001)

Length : 5M

<Controller>

Equipment

(PLC, etc.)

04

1:1 Type

(SXN-10T)

Head Cable

(SOC-XN-1-001)

Head Cable

(SOC-XN-1-001)

Head Cable

(SOC-XN-1-001)

Length : 15M

Length : 15M

<Head>

<Head>

(SXH-10T)

(SXH-10T)

(SXH-10T)

(SXC-10T)

(SXC-102T)

(SXC-104T)

<Head>

<Controller>

<Controller>

<Controller>

Length : 15M

1:2 Type

(SXN-102T)

1:4 Type

(SXN-104T)

Instruction Manual

 

SXN-10T

Eng

01

Head

SXH-10T

1~4 ea

Controller

SXC-10T, SXC-102T, SXC-104T

1 ea

Fixing Bolt

SFB-XN-1-001

1/4”-20unc x 15L/ 1~4ea
1/4”-20unc x 8L/ 1~4ea
M4 x 0.7Pitch x 10L/ 2~8ea 

*

Head Cable

SOC-XN-1-001

15m / 1~4ea

*

D-Sub Cable

SDC-SN-4-001

25Pin / 5m / 1ea

*

Power Cable

SPC-MT-1-001

AC 100V, 50/60Hz, 1.8m / 1ea

          or
Power Cable

SPC-MT-2-001

AC 220V, 50/60Hz, 1.8m / 1ea

*

*

Head

M4 x 10L

 Fixable Object

Mounting Bracket

1/4”-20UNC x 15L or 8L

M4 x 10L

2

Check the package contents

▶ Product compositions

      The package includes the following products composition.

1

The matters of safety

*  Do not fabricate or do maintenance by yourself. Malfunction, Electric shock, and fire danger are considered.
    Contact us directly if you need the item to be repaired.
*  Do not let the water touch the product. It may cause electric shock or fire due to malfunction.
*  When you check or maintain the product, make it sure you turn off the power.
    It may cause electric shock or fire due to malfunction.
*  The item should be fixed to the target tightly. Electric discharging or breakage might happen.
*  Please shield your installing circumstances first since the item releases the soft X-ray.
    Direct X-ray exposure is not recommended owing to cause health problem.
*  It includes a beryllium window on the X-ray tube unit in order to release soft X-ray for ionization. 
    This beryllium material can cause respiratory disorder only if the person gets exposed to forms of either 
    beryllium powder or smoke. However, our device doesn't creat beryllium in neither of the mentioned forms.
    Please be careful not to break the device since there might be a slight chance that the device could partially
    degrade into the powder form, then it can cause harm defects. If the user touches the beryllium material 
    on the device, clean oneself on the running water or rinse it off with soap directly. 
    If the beryllium windonw gets dirty or damaged, call us directly for assistance.  
*  Do not use the product at the place where dangerous material such as inflammable or ignitable
    material exists. This product is not the product of anti-explosive type.
*  This device is made only for industrial uses. You need to ground the device beforehand.
    Otherwise, there are in case of malfunction, electric shock, or fire damage.  

*  Do not disconnect the head cable with power applied. There is a possibility of electric shock or malfunction.
*  Connect wires referring to the product manual. Wrong connection can cause failures.
*  For your proper cable connection, take a look at the manual 「Installation & Connection」 for references. 
    Any disordered connection is detected, the malfunction might arise. 
*  All cables should be connected all the time. Please careful of cable disconnections. If power or 
    communication cables got damaged, replace them immediately. Malfunction and fire danger may happen.
*  Do not install the device where the vibration can be detected.
    Any minor impact or vibration on the device, the malfuction or danger of accident might happen.
*  Do not use the item off the range of usage(Electrostatic elimination).  
    Malfunction or danger of accident may occur.
*  If you wish to discard the head unit of X-ray device, you need to report for disuse declaration to the 
    institution(s) where they ask to. A proper declaration procedure is neccesary in order to disuse X-ray device.
*  Please contact to either Korea Institute of Nuclear Safety(KINS) or a safety supervisor of Sunje directly.

It is recommended that only persons who have sufficient knowledge and experience such as system
designers and responsible persons deal with this product after carefully reading the product manual.

3

Nomenclatures of parts

Mounting Bracket

A bracket to fix 
the item on the 
facing target.

Indicator Light 

Soft X-Ray Window

The X-ray radiation will be
released through this 
beryllium window from the
head unit of X-ray ionizer. 

Controller Connector

A connector to wire the 
head unit and controller.

Operating indicator

Tube replacement 
Alarm indicator

Malfunction Indicator

▶ Controller Unit(SXC-10T / 102T/ 104T)

      ※ The following is a standard image of SXC-104T. The image might differ according to other models. 

▶ Head Unit (SXH-10T)

Front

indicator Light 

LCD Display

Hours of Head use
and operation condition
will be displayed. 

Signal Input/Output Connector

Use it when various signals 
(input/output) are necessary.

Head Connector

A connector that
links the head unit
and controller.

Power Connector

Using it when 
power supply.

Fuse Socket

When opening a socket, there is 
a fuse inside. Please clarify your 
proper specification when replacing.

Power Switch

A switch for supply/cut
the power. 

Head Selection Button(102T, 104T only)

This is for when you want to
select an individual head from the
whole connections.

Run/Stop Button

It is a run/stop button
in order to operate
a soft X-ray Ionizer.

Blue LED will be on once the controller is powered on.

For user's safety purpose, Green LED will be on when 
interlock is safely contacted. (If the light is not on, the 
head unit is not in working condition) 

Once the unit reaching 7,500hrs of operation, 
Orange LED will be on.

when false operation, Red LED will be on.

Blue LED will be on the head you select among the 
ones(Head1 or 2) are connected to a controller.

Power indicator

Safety(Interlock) 
Indicator

Tube replacement 
Alarm Indicator

Malfunction Indicator

Head Selection 
Indicator

Rear

4

Installation and connection

■  Shielded room
■  There must be no objects between the 
      target area and X-ray device.
■  No vibration on the fixed device. 

■  Be aware of any flammable or ignitable 
      materials around the working area.
■  Secure to have enough working space for 
      quick maintenance of the device. 

▶ Check the installation conditions head unit

      Please check the installation condition whether it meets proper specification.

▶ Head unit fixing

      Fix the target product on the fixed area where you install by using supported fixing bolt(s).

See the following graph for references. Select the ideal tickness and quality of shielding material.

* Please shield the area where the customer is willing to install the soft X-ray device
   for safety issue. 
* After shielding process, please connection to your own interlock system to operate
   the X-ray device On/Off when the door is opened/closed. 

▶  Shield installation compositions

      Please refer to the "Installation Compositions" for your references. Please keep your working 
      environment of the leakage radiation level within the range of 10μSv/hr all the time. 

No.

Shield Material

Thickness [mm]

Copper

Over 0.4

Aluminium

Over 2.0

Glass 

Over 3.0

PVC

Over 5.0

Acrylic

Over 40.0

Head Cable

Interlock

 Controller

Head Unit

Shield Door

Shield

▶ Shielding methods

Shielding material selection

Please connect the head and controller unit with supported "Head Cable".

▶  How to connect 

Connecting the Head Unit

Using supported ground and power cables to connect the controller.

Connecting the Earth Ground and Power

Please connect the controller and external machinery equipment with supported "D-Sub Cable".

Connecting the Input & Output Signal

Input/Output Signal Cable Specifications

Division

No.

Pin Name

Labeling

Color

Function

INPUT

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

Remote On

Remote Off

Common

Interlock

Interlock

Remote(N.O)

Remote(Com)

Remote(N.C)

Interlock(N.O)

Interlock(Com)

Interlock(N.C)

Not Used

Ground

Power (N.O)

Power (Com)

Power (N.C)

Over Time (N.O)

Over Time(Com)

Over Time (N.C)

Alarm (N.O)

Alarm (Com)

Alarm (N.C)

Not Used

Rs-485(+)

Rs-485(-)

RMT-ON

RMT-OFF

RMT-COM

INT-ON

INT-OFF

RE-N.O

RE-COM

RE-N.C

IN-N.O

IN-COM

IN-N.C

-

-

POW-N.O

POW-COM

POW-N.C

HEAD-N.O

HEAD-COM

HEAD-N.C

AL-N.O

AL-COM

AL-N.C

-

RS-485+

RS-485-

Black

White on Black

Brown

White on Brown

Red

White on Red

Orange

Black on Orange

Yellow

Black on Yellow

Green

-

Black

White on Green

Blue

White on Blue

Violet

White on Violet

Gray

Black on Gray

White

Black on White

-

Pink

Sky Blue

Remote 

On / Off

(Electrical Contact )

Interlock

On / Off

(Electrical Contact )

OUTPUT

Remote  
On / Off 

State Output

Interlock
On / Off 

State Output

-

-

Power 

On / Off

State Output

Over Time

State Output

Alarm(Head Fail)

State Output

-

RS 485

RS 485 

Communication

Reviews: