The compressor (shown at left) is located toward
the base of the booth in the same column as the
touchscreen. Remove the panel to access the
compressor.
External
Compressor Filter
Bleed-off Valve
Compressor
Regulate the PSI
here using the
black cap. The
silver locknut
holds the cap in
position.
Adjust the bleed-off valve to regulate the
compressor PSI. If the pressure is HIGH (above
20.5 PSI), open the valve more to reduce the
pressure and allow more to escape.
If the pressure is LOW (below 18.5 PSI), close
the valve more to increase pressure. Adjust in
increments so you do not over compensate.
Check the Technical > Diagnostic Outputs page
again, and adjust until the compressor PSI is
within the tolerance range.
To adjust the air compressor, open either the
Staff >
Tools > Purge
option
OR
the
Technical > Diagnostic
Outputs > Compressor
option (both show PSI value).
Use this to monitor the current PSI output from the
compressor. To alter the PSI, adjust the black cap with
your fingers, allowing the silver locknut to move
freely. While adjusting the black cap, trigger the
touchscreen to view the PSI output using either screen
mentioned above. Once it is within the target range
(18.5-20.5, ideally 19.5), firmly hold the black cap to
retain its position and hand tighten the silver locknut
down to the base (as shown in image).
Black Cap- hold
in position while
tightening silver
locknut
Silver Locknut-
hand tighten
down to base to
retain position