If no obstructions, replace horizontal motor
104
Vertical motor current below minimum
mA during enable
Vertical motor current under powered. Session will be
cancelled.
•
Check Vertical Motor fuse on DC board
•
Check voltage at motor (24V DC)
•
If you have voltage at the motor, replace motor
•
If no voltage at the motor, check voltage
coming off the board
•
If Voltage at the board, replace cable
•
If No Voltage at the board, replace board
105
Horizontal motor current below minimum
mA during enable
Horizontal motor current under powered. Session will
be cancelled.
•
Check Vertical Motor fuse on DC board
•
Check voltage at motor (24V DC)
•
If you have voltage at the motor, replace motor
•
If no voltage at the motor, check voltage
coming off the board
•
If Voltage at the board, replace cable
•
If No Voltage at the board, replace board
106
Session auto-cancelled - Start sensor not
activated within 16 minutes after enable
Start sensor idle for 16 minutes after queuing a session.
The session will be cancelled.
107
Air compressor current exceeded
Compressor current is above maximum of 7 for 115v or
3.5 for 230v. Session will be cancelled.
•
Check wall voltage during session
•
If it’s below 208 V AC during session,
electrical needs to be brought up to spec
•
If it’s above 208 V AC during session, go to
Technical/Diagnostic Outputs and turn on
Compressor
•
If it does not run or sounds irregular, replace
compressor
108
Air compressor current too low
Compressor current is below 1.8 amps AND air pressure
is below 16 PSI. Session will be cancelled.
•
Check compressor fuse on AC board, replace if
bad
•
Check for AC Voltage at the compressor
•
If Voltage is good, replace compressor
•
If no voltage at the compressor, check voltage
at board
•
If no voltage at the board, replace board
•
If voltage is coming off the board, replace
compressor
109
Unable to communicate with AC board to
set outputs
Internal communication error. Session will be cancelled
after communication lapse exceeds timeout.