Mystic Tan Kyss™
Owner’s Manual
49
Appendix 2: Technical Diagnostic Output Tolerances
The Technical > Diagnostic outputs screen provides significant data about the various booth
systems during operation. Below are the recommended range tolerances for the various systems.
If a displayed value deviates from the range shown, there could be a problem with the
component. Remember that the Drain Pump and the Exhaust Fan cannot run at the same time.
The target value is the ideal operating value. Values within the low to high range are acceptable.
Compressor Specs
Low Value
Target Value
High Value
Compressor Amperage
2.2 A
2.7 A
3.1 A
Air Pressure PSI
18.5
19.5
20.5
Top Heater Specs*
Low Value
Target Value
High Value
Top Heater CT A
2.2
2.6
3.0
Bottom Heater Specs*
Low Value
Target Value
High Value
Bottom Heater CT A
2.2
2.7
3.0
Heater Fan (spike)*
Low Value
Target Value
High Value
Fan Amperage
0.35
0.42
0.48
Heater Fan (operating)*
Low Value
Target Value
High Value
Fan Amperage
0.25
0.30
0.34
Exhaust Fan
- Value is either OFF (0) or ON (1). During ON the Exhaust Fan should run.
Wash Solenoid
- Value is either OFF (0) or ON (1). Activation should toggle between states.
Start Lamp
- Value is either OFF (0) or ON (1). During ON the start sensor should illuminate. In
the ON state, the start sensor does not blink.
Drain Pump
- Value is either OFF (0) or ON (1). During ON the Drin Pump should run.
Vertical Motor (spike)**
Low Value
Target Value
High Value
Vertical Motor mA
0.06
0.08
0.09
Vertical Motor (operating)**
Low Value
Target Value
High Value
Vertical Motor mA
0.04
0.05
0.06
*NOTE ON FAN VALUES: Fan Heaters spike in the first moment of operation, and then
level out to a constant value. The spike value accounts for the first seconds of operation, and
should then drop to the operating value.
**NOTE ON MOTOR VALUES:
Motor values will spike in the first moment of operation,
and then level out to a constant value. The spike value accounts for the first seconds of
operation, and should then drop to the operating value.
The swivel motor has a much larger operating range than the vertical range and will vary
during operation. This is denoted by a low, target, and high range as opposed to a set value.