background image

4

5

OPERATING MODES:

The Saturn

 4 has three operating modes. This selection depends on the type of devices being 

connected to the controller. Press the Select Mode button to change from MODE A, B or C. A 

green

 LED will let you know what MODE you are operating in.

Mode A:

  This mode independently lowers your temperature and humidity.  If you are connecting 

a cooling device (such as a exhaust fan) to lower the temperature AND a dehumidifier to lower 
the humidity level, the controller will activate these devices independently based on the tempera-
ture and humidity levels in your grow room and your preferred set points. The ‘Cooling Output’ 
is activated when the temperature set point is exceeded and the ‘Humid/Dehumid Output’ is 
activated when the humidity set point is exceeded

Mode B:

  This mode simultaneously lowers your temperature and humidity.  If you are connect-

ing a cooling device (such as an exhaust fan) to lower your temperature AND a dehumidifier to 
lower the humidity levels, the controller will activate the devices simultaneously if the temperature 
rises above the set  point AND/OR  the humidity level rises above the set  point. The ‘Cooling 
Output’ and ‘Humid/Dehumid Output” will both be activated until both the temperature and/or 
humidity set point is reached.

Mode C: 

 This mode independently lowers the temperature and increases the humidity.  If you’re 

connecting a cooling device (such as a fan) to lower your temperature AND a humidifier to raise 
the humidity level, the controller will activate these devices independently based on the tempera-
ture and humidity levels in your grow room and your preferred set points.  The ‘Cooling Output’ 
is activated when the temperature set point is exceeded, and the ‘Humid/Dehumid Output’ is 
activated when the humidity set point is exceeded.  

Troubleshooting Tips

•  The Saturn™ 4 has no power?

 Verify power source is providing 120 Volts A/C.  Reset 

the circuit breaker on the Saturn

 4 by turning OFF the unit, then turn ON.  

•  The circuit breaker keeps tripping on my Saturn™ 4? 

Check to see  

that you are not exceeding the maximum amperage (14.5 Amps) of the Saturn

 4.  

•  The CO

2

 Output is not working? 

This could be because your Saturn

 4 is not exposed 

to light.  Put the Saturn

 4 in a location in your grow room so that the PHOTOCELL is not 

shaded or covered from lights. It also could be because your Cooling Output is active. 
When this occurs it deactivates the CO

2

 Output so you don’t ‘dump your room’ and 

exhaust all the CO

2

 you’ve injected.

•  The MODE LED’s are flashing? 

The Saturn

 4 has detected a problem with the remote 

sensor.  This can normally be remedied by turning OFF the Saturn

 4 & disconnecting the 

sensor, then re-attaching the sensor back to the Saturn

 4 and turn the unit back ON.  

The Saturn

 4 should be functioning properly again.  If not, contact our Technical Service 

Specialist at 888-808-4826 to assist you further.

•  The humidity is increasing instead of decreasing or decreasing instead of increas-

ing?

 Verify that your MODE is correct.  MODE’s A & B are used to decrease humidity and 

MODE C is used to increase humidity.

Controller Specifications

Size = 9”H x 7”W x 3 ¾ “D 

 

Input Voltage = 120 Volts
Output Voltage = 120 Volts 

 

Maximum Amperage = 14.5 Amps
Operating Hertz = 60 Hz.
Minimum/Maximum Humidity Control Levels = 5% to 95% RH (non-condensing)
Humidity Accuracy = +/-3% RH of desired setting

Humidity Deadband = 5% RH
Minimum/Maximum Temperature Controls = 41°F to 113°F
Temperature Accuracy = +/- 1°F
Temperature Deadband = 3°F

Warranty Information

•  Titan Controls

®

 warrants the original purchase of this product against defects in material 

and workmanship under normal use for three (3) years from the date of purchase.

•  During the warranty period, Titan Controls

®

 will, at our option, and without charge, repair 

or replace this product if the controller or any of its components fail or malfunction.

•  All returns or repairs must be accompanied by a Return Merchandise Authorization (RMA) 

number prior to any service of the product.

•  This warranty is in lieu of all other warranties, expressed or implied, including the warran-

ties of merchantability and fitness for use, and of all other obligations or liabilities on the 
part of the seller.

•  This warranty shall not apply to this product or any part thereof which had been damaged 

by accident, abuse, misuse, modification, negligence, alteration or misapplication.

•  Controllers with serial numbers or date tags that have been removed, altered or obliterat-

ed; broken seals that show evidence of tampering or nonconforming parts, are excluded 
from coverage.

•  Titan Controls

®

 makes no warranty whatsoever in respect to accessories or parts not 

supplied by Titan Controls

®

.

•  Monetary refunds of the warranty will not be given.
•  The Buyer assumes all responsibility regarding the proper use & installation of this controller.
•  All warranty service is provided through the Titan Controls

®

 factory.

•  This warranty shall apply only to the United States, including Alaska, Hawaii & territories of 

the United States and Canada.

•  Defective controllers are required to be returned with the 

“proof of purchase/receipt”

 for 

warranty coverage.

•  For additional warranty information, contact the Titan Controls

®

 Technical Service Repre-

sentative at 888-808-4826 or your local Dealer.

•  NOTE: Titan Controls

®

 is a Manufacturer of environmental, timing, lighting, ventilation and 

CO

2

 controls. All sales offerings to the public are done through a nationwide group of 

Dealers. No sales offerings will be made directly to the general public.

Service & Repair Program

•  For all service and repairs, please contact by our Technical Service Representative at 888-

808-4826 for troubleshooting your gear and attaining a Return Merchandise Authorization 
(RMA) number, if applicable.

•  All factory service & repairs will be completed within 48 hours of receipt of controller at the 

factory.

•  Titan Controls

®

 will, at its discretion, repair or replace the controller.

•  Factory calibration services are available for all Titan Controls

®

•  Returning Units: Please contact your retail store for information regarding returns. 

Summary of Contents for TITAN Controls Saturn 4

Page 1: ..._________________________________ _________________________________________________ _________________________________________________ _________________________________________________ _________________________________________________ ________________________________________________ 1 Square 1 Foot VANCOUVER WASHINGTON U S A www titancontrols net Revision H 2 19 2013 Titan Controls ...

Page 2: ...a circulation fan or other devices during the nighttime hours The Saturn 4 provides you with the total control you re looking for in your garden Titan Controls keepin it simple Include the following if returning directly to Titan Controls Proof of purchase copy This completed form RMA on the outside of the box Return Merchandise Authorization Number Required Dealer Customer s Name ________________...

Page 3: ...me period only It will deactivate when the Cooling Output is activated By achieving this you are not ventilating the CO2 as you re enriching your grow area and wasting your CO2 NIGHT OUTPUT The outlet can be used for a variety of devices that only require power at night This outlet acti vates only during the nighttime period HUMIDITY OUTPUT This output is for use with a humidifier or dehumidifier ...

Page 4: ...of decreasing or decreasing instead of increas ing Verify that your MODE is correct MODE s A B are used to decrease humidity and MODE C is used to increase humidity Controller Specifications Size 9 H x 7 W x 3 D Input Voltage 120 Volts Output Voltage 120 Volts Maximum Amperage 14 5 Amps Operating Hertz 60 Hz Minimum Maximum Humidity Control Levels 5 to 95 RH non condensing Humidity Accuracy 3 RH o...

Reviews: