SL8SA- INSTRUCTIONS 

Page 3 of 4 

 

5) SYSTEM SETUP

 

 
Four options are available under system setup; 

SET SYSTEM CLOCK / FACTORY SETTINGS / SOLAR PARAMETERS / EXIT. 

 

EXIT

 - will return you to 

5) SYSTEM SETUP

 with no changes. 

SET SYSTEM CLOCK

 – allows you to adjust calendar and time of day. 

FACTORY SETTINGS

 – restores all the settings to the factory default state. 

SOLAR PARAMETERS 

– for setting the solar start and end times. 

 
Solar parameters; 

SOLAR START TIME 

SOLAR END TIME   

HOUR (24H) XX   

HOUR (24H) XX 

 
The start time is the time of day ‘hour’  that the solar pump is allowed to start. The solar end time is the time of day 
‘hour’ at which the pump will stop. 
**Default time the solar pump is allowed to operate is from 08:00 to 19:00. 
Adjust values by pressing the 

Up/Down

 buttons, to accept the setting press the 

Enter

 button. 

 

6) SAVE & EXIT

 

 
When this menu is selected, push 

Enter

 to save ALL settings, the unit will return to normal operation automatically. 

Note: If any of the menu items are left unattended for 3-4 mins the menu will time out and automatically save all 
settings and return to operation. 

 
The 

ENTER/MANUAL

 button 

 

FOR MANUAL MODE 

PRESS ENTER NOW 

 
Pressing the 

Enter

 button once will display the above message for ~3 seconds, simply wait and the unit will return to 

normal operation. (this can also be used to bypass the 3 minute minimum run time). 
 
If you 

Enter

 is pressed for a second time within a 3 second period, the display will indicate you have entered Manual 

mode, operation is the same as manual mode in the menu with the only difference being the timeout value is 4 Hours. 
 
NOTES. 
 
1.

 

If a sensor fault is detected the V7 will display which sensor and what the fault is. 

2.

 

Should power be interrupted for any reason, the V7 will resume normal operation when power is restored, all 
information will have been kept. 

3.

 

Temperature sensors used with this unit are Digital and are accurate to 0.5 Deg. C, no calibration is required. 

4.

 

The sensor cable with the thin trace is the positive and is usually fitted to the right hand side of the green plug, 
incorrect polarity will be displayed. 

5.

 

The heater interlock switching is used the maximum load is 5A at 32Vac max. 

 