ratings, conductor current ratings, fuse sizes, and size of controls connected to the PV output.   

 

Only use same or connectable connectors to connect eArc to form a string, or connect to another device. 

Removing the connectors will void the warranty. 

 
 

Fire safety 

 

Consult your local authority for guidelines and requirements for building or structural fire safety. 

 

Roof constructions and installations may affect the fire safety of a building; improper installation may 

create hazards in the event of a fire. 

 

Use components such as ground fault circuit breakers and fuses as required by local authority. 

 

Do not use panels near equipment or in places where flammable gases may be generated. 

 

eArc have been rated Fire Class C, and are suitable for mounting on to a Class A roof. 

 
 

Production Identification 

Each eArc has two labels providing the following information: 

 

Nameplate: describes the product type; rated power, rated current, rated voltage, open circuit voltage, 

short  circuit  current,  all  as  measured  under  standard  test  conditions;  weight,  dimensions  etc.;  the 

maximum system voltage is 1000 volts. 

 

Barcode: each individual eArc has a unique serial number. The serial number has 18 digits. The 1th to 

4th digits are the module type for internal use, and the 5th and the 6th digits are the year code, and 

the 7th and 8th digits are the month and the 9th and the 10th digits are the week code, and the 11th 

and the 15th digits are order number, and the 16th and the 18th digits are the sequence codes. For 

example, XXXX160417XXXXXXXX means the module was made in the 17th week of 2016. Each module 

has only one bar code. It is permanently attached to the interior of eArc and is visible from the top front 

of eArc. This bar code is inserted prior to lamination. 

 

 
 

Mechanical Installation 

Selecting the location 

 

Select a suitable location for installing eArc. 

 

eArc should face south in northern latitudes and north in southern latitudes. 

 

For detailed information on the best installation angle, refer to standard solar photovoltaic installation 

guides or consult a reputable solar installer or systems integrator. 

 

eArc  should  not  be  shaded  at  any  time.  If  an  eArc  is  shaded  or  even  partially  shaded,  it  will  fail  to 

Summary of Contents for eArc SMA160M-4X09DW

Page 1: ...eArc PV System Installation Manual...

Page 2: ...his guide Features Benefits Notices General safety Handling safety Installation safety Fire safety Production Identification Mechanical Installation Grounding Electrical installation Disclaimer of lia...

Page 3: ...tion For any questions please contact SUNMAN s Customer Service Department or our local representatives for more detailed information Installers should follow all safety precautions described in this...

Page 4: ...w sunman energy com version 2019A page 2 18 TM Features Benefits Flexible layouts eArcTM PV system can be installed at any shape roofs which has integrated appearance with buildings Maximization insta...

Page 5: ...s required for eArcTM PV System PV arrays Copyright and Trademark Information Copyright 2019 by Sunman Zhenjiang Company Limited All rights reserved eArc and the SUNMAN logo are trademarks of Sunman Z...

Page 6: ...d mounted mounted on rooftops vehicles or boats The proper design of support structures lies within the responsibility of the system designers and installers Do not use mirrors or other magnifiers to...

Page 7: ...nections or unplug connectors while the circuit is under load Contact with electrically charged parts of the panels such as terminals can result in burns sparks and lethal shock whether or not the pan...

Page 8: ...ated current rated voltage open circuit voltage short circuit current all as measured under standard test conditions weight dimensions etc the maximum system voltage is 1000 volts Barcode each individ...

Page 9: ...ing eArc with a tilt angle of at least 10 degrees making it easier for dust to be washed off by rain Always keep the back sheet of the panel free from foreign objects plants and vegetation or structur...

Page 10: ...steel roof sheeting Any other roof sheeting requires consolation with Sunman or its local importer b Size of color steel roofing c Preparation of bonding material Prepare silicone nozzle by cutting a...

Page 11: ...n to clean cloth Wiping down the roof apply to the adhesion area Reapply until clean Leave to dry e Install chemical bonding material Apply the silicon with the nozzle perpendicular to the roof The le...

Page 12: ...manual are subject to change without notice www sunman energy com version 2019A page 10 18 TM f Layout of SMD Series Layout For SMD Series SMDxxxM 6X12DW SMDxxxM 6X12UW SMDxxxM 6X10DW SMDxxxM 6X10UW...

Page 13: ...o not install using quick bonding method when rain is present Do not install using quick bonding method when wind speeds greater than 10m s are present at the site within 24 hours Roof and ambient tem...

Page 14: ...be properly secured to their supports so that they can withstand the pressure of the load including the rise and pressure of the wind It is the responsibility of the installer to ensure that the moun...

Page 15: ...always grounded SUNMAN recommends always refer to local state and national code requirements for PV module grounding SUNMAN highly recommends negative grounding if it s allowed by local authorities W...

Page 16: ...ding is achieved by bonding all conductors on the module frame and metal mounting structures continuously with a suitable grounding conductor Third party grounding solutions are acceptable These solut...

Page 17: ...ort circuit current The recommended cable is PV wire temperature rating is 90 with a cross section of at least 2 5mm Please refer to local regulations to determine the system wires size type and tempe...

Page 18: ...1 9 52 1662mm X 1019mm X 5 6mm 5 5kg 20A 20 SMD290M 6X10DW 290 32 6 8 90 39 9 9 43 1662mm X 1019mm X 5 6mm 5 5kg SMD285M 6X10DW 285 32 4 8 80 39 7 9 34 1662mm X 1019mm X 5 6mm 5 5kg SMD280M 6X10DW 280...

Page 19: ...m X 995mm X 35mm 7 6kg 20A 20 SMA290M 6X10DW 290 32 6 8 90 39 9 9 43 1638mm X 995mm X 35mm 7 6kg SMA285M 6X10DW 285 32 4 8 80 39 7 9 34 1638mm X 995mm X 35mm 7 6kg SMA280M 6X10DW 280 32 2 8 70 39 5 9...

Page 20: ...X 665mm X 35mm 6 4kg SMA225M 4X12UW 225 25 5 8 83 31 3 9 36 1983mm X 665mm X 35mm 6 4kg SMA220M 4X12UW 220 25 2 8 74 31 1 9 27 1983mm X 665mm X 35mm 6 4kg SMA215M 4X12UW 215 24 9 8 64 30 9 9 18 1983mm...

Page 21: ......

Page 22: ......

Reviews: