24
¤¤
Settings
-------------
£
Maxtemp tank1
149°F
dT Max tank1
49°F
dT Min tank1
38°F
Maxtemp tank2
149°F
dT Max tank2
49°F
dT Min tank2
38°F
Mintemp prio tank
32°F
2.
Setting Menu:
This menu allows you to set all adjustable
parameters of your system.
Not all options are available with all systems.
2.1. Maxtemp tank1:
Maximum value of desired water temperature in
tank1
during normal operation.
(Adjustable from 59°F to 203°F with factory default set at 149°F)
2.2. dTMax tank1:
'LIIHUHQFHǻ7EHWZHHQFROOHFWRUWHPSHUDWXUH
T1
) and
tank1
temperature (
T2
) that will
automatically engage
pump1
.
(Adjustable from 7°F to 72°F with factory default set at 12°F)
2.3. dTMin tank1:
Difference (
ǻ7
) between collector temperature (
T1
) and
Tank1
temperature (
T2
) that will
automatically disengage
pump1
.
(Adjustable from 4°F to 63°F with factory default set at 5°F)
NOTE: dTMin will always be 3-7°F less than dTMax
2.4. Maxtemp tank2:
Only applicable on systems with two tanks (as discussed in sections
1.4.2 /
System 2
and
1.4.3 / System 3
)
.
Sets the maximum value of desired water temperature on the
tank2
.
(Adjustable from 59°F to 203°F with factory default set at 149°F)
2.5. dTMax tank2:
Only applicable on systems with two tanks (as discussed in sections
1.4.2 /
System 2
and
1.4.3 / System 3
).
Difference (
ǻ7
) between collector temperature (
T1
) and
tank2
temperature (
T4
) that will
automatically engage
pump1
with
system2
or
pump2
with
system3
.
(Adjustable 7°F to 72°F with factory default set at 12°F)
2.6. dTMin tank2:
Only applicable on systems with two tanks (as discussed in sections
1.4.2 /
System 2
and
1.4.3 / System 3
).
Difference (
ǻ7
) between collector temperature (
T1
) and
tank2
temperature (
T4
) that will
automatically disengage
pump1
with
system2
or
pump2
with
system3
.
(Adjustable from 3°F to 63°F) with factory default set at 5°F)
NOTE: dTMin tank2 will always be 3-7°F less than dTMax tank2
Tank1
T2
(°F)
dTMin
dTMax
P1
Collector
T1
(°F)
Maxtemp
Tank1
dTMax
dT = T1 – T2
100%
0%
dTMax
Pump speed regulation
Note:
If the installed system
has two tanks, the adjacent
graph is also valid when using
the sensor information from
the second tank.