29
¤¤
Settings
--------------
dT Max tank1
49°F
dT Min tank1
38°F
Min rev pump
50%
dTFS
59°F
Mintemp coll.
32°F
Antistagnation
£
Start
230°F
2.16. Anti-stagnation
2.16.1. Start
When the temperature of the fluid in the collector rises above this setting, the designated
valve or pump is activated.
(Adjustable from 32°F to 392°F with factory default set at 230°F)
2.16.2. Stop
When the temperature of the fluid in the collector falls below this setting, the designated
valve or pump disengages.
(Adjustable from 32°F to 302°F with factory default set at 200°F)
2.16.3. Output option
This feature allows you to choose to use either
P1/P3
(both) or
P3
(only) to circulate the fluid.
¤¤
Service
--------- - --- --
English
Time and date
US Version
yes
System
Extra
off
£
Extra antistagnation
--
Protection func.
¤¤
Settings
--------------
dT Min tank1
38°F
Min rev pump
50%
dTFS
59°F
Mintemp coll.
32°F
Antistagnation
Start
230°F
£
Stop
194°F
¤¤
Settings
--------------
Min rev pump
50%
dTFS
59°F
Mintemp coll.
32°F
Antistagnation
Start
230°F
Stop
194°F
£
Output option
P1/P3