8
1.4. System:
When the line is selected, press
(
>
)
to enter the submenu.
You have the choice between 8 systems with the option to add an extra function (see
1.5
).
1.4.1. System 1
Basic system, with 1 tank, 1 pump, 1 collector array and 2 sensors.
With this system you can add extra functions with 1 or 2 sensors (
Booster pump
,
Thermostat
,
Cooling, Anti-stagnation,
or
Diffcontrol
function).
1.4.2. System 2
System with 2 tanks, 1 pump, 1 valve, 1 collector array and 3 sensors.
With this system you can add an extra function with 1 sensor (
Thermostat
,
Cooling, or Anti-
stagnation
function).
1.4.3. System 3
System with 2 tanks, 2 pumps, 1 collector array and 3 sensors.
With this system you can add an extra function with 1 sensor (
Thermostat
,
Cooling, or Anti-
stagnation
function).
System
1
T1
T2
T1 _ _ _°F
T2 _ _ _°F
P1 _ _ _ %
System
2
T1
T1 _ _ _°F
T2 _ _ _°F
T4 _ _ _°F
P1 _ _ _ %
T2
T4
1
2
P1
P2
System
3
T1
T1 _ _ _°F
T2 _ _ _°F
T4 _ _ _°F
P1 _ _ _ %
P2 _ _ _ %
T2
T4
1
2
Summary of Contents for ADVANCED SOLAR CONTROLLER