SunMaxx Solar | 5098 NY 206 Bainbridge NY 13733 | 1.877.786.6299 1.877.270.7875 fax | www.sunmaxxsolar.com
1. Measurement Values
The menu “1. Measurement values” serves to display the currently measured temperatures.
The menu is closed by pressing “esc” or selecting “Exit measurement values”.
Selecting “Overview” or “esc” exits the Info mode.
CAUTION
If “--” appears on the display instead of the measurement value, then there may be a defective or incorrect temperature sensor. If
the cables are too long or the sensors are not placed optimally, the result may be small deviations in the measurement values. In
this case the display values can be compensated for by making entries on the controller. Follow the instructions under “6.7. - Sen-
sor calibration” on page 47.
What measurement values are displayed depends on the selected program, the connected sensors and the specific device design.
2. Statistics
The menu “2. Statistics” is used for function control and long-term monitoring of the system.
The menu is closed by pressing “esc” or selecting “Exit statistics”.
CAUTION
For analysis of the system data it is essential for the time to be set accurately on
the controller. Please note that the clock does not continue to run if the mains
voltage is interrupted, and must therefore be reset. Improper operation or an in-
correct time may result in data being deleted, recorded incorrectly or overwritten.
The manufacturer accepts no liability for the recorded data!
2.1 OPERATING HOURS
Display of operating hours of the solar pump connected to the controller; various time ranges (day-year) are available.
2.2 HEAT OUTPUT
Display of the heat output of the system.
2.3 GRAPHIC OVERVIEW
This provides a clearly-organised display of the data listed under 2.1-2.2 as a bar graph. Various time ranges are available for comparison. The two
left-hand keys can be used to page through the data.
2.4 MESSAGE LOG
Display of the last 20 events occurring in the system with indication of date and time.
2.5 RESET / CLEAR
Resetting and deleting the individual analyses. The function “All statistics” clears all analyses but not the error messages.