6.4.2.3 Thermostat Sensor 1
T set is measured with thermostat sensor 1.
When thermostat sensor 2 is connected, the relay switches on when T set is undershot at thermostat Sensor 1, and switches off when T set +
hysteresis at thermostat sensor 2 is exceeded.
Settings range: S1-S8, VFS1-2, active storage / Default setting: none
6.4.2.4 Thermostat Sensor 2
Optional switch off sensor
When T set + hysteresis is exceeded at the optional thermostat sensor 2, the relay is switched off.
Settings range: S1-S8, VFS1-2, active storage / Default setting: none
RELA
Y FUNC
TIONS
6.4.2.5 T Eco
For Energy saving mode
When Energy saving mode is active: During solar charge T eco is used instead of TH set. When the temperature drops below T eco at thermostat
sensor 1, the relay is switched on and heats up to T eco + hysteresis.
Settings range: 0°C - 100°C (32°F to 212°F) / Default setting: 40°C (104°F)
6.4.2.6 Storage
For Energy saving mode
Loading this storage activates the Energy saving mode when this storage is charge by solar, additional heating is only switched on when the tem-
perature is below T eco.
Settings range: (Storage sensors) / Default setting: first storage
6.4.2.7 Energy Saving Mode
Energy saving mode switches the heating on when T eco is undershot and heats up to T eco + hysteresis when solar charge is active.
Settings range: On, Off / Default setting: Off
6.4.2.8 Periods
Thermostat activity times
Set the desired periods of time when the thermostat should be active. 3 periods can be set per day, settings can also be copied to other days.
Outside the set times the thermostat is switched off.
Setting range: from 00:00 to 23:59 /default setting: 06:00 to 22:00
6.4.3 Thermostat 2
Thermostat is used for time- and temperature controlled additional heating.
See Thermostat 1