This menu determines the sensor for the room temperature.
Settings range: S2 to S7, RC
6.4.16.3 Room Sensor
Set the desired periods of time when the heat circuit day mode should be active. 3 periods can be set per day, settings can also be copied to
other days. Outside the set times the heating function is working in night mode.
Setting range: from 00:00 to 23:59 /default setting: 06:00 to 22:00
6.4.16.4 Periods
6.5 HEAT QUANTITY
When the heat meter mode “Flow rate” is selected, an approximated heat quantity is calculated using the values the user has to enter. These are
type of glycol/AntiFreeze, glycol portion and flow rate. These values are put into correlation with the temperature data of collector sensor and
storage sensor. If necessary a correction value for ΔT can be set: Since for the heat meter the collector and the storage temperature are used, a dif-
ference to the flow respectively return flow temperature can be compensated by changing Offset ΔT accordingly.
Example:
Displayed collector temp. 40°C (104°F), measured flow temperature 39°C (102°F), displayed storage temperature 30°C (86°F), measured return
temperature 31°C (87°F) = results in a correction value of -20% (displayed ΔT 10K, real ΔT 8K = -20% correction)
6.5.1 Constant Flow
CAUTION
The heat quantity measured in the mode “Flow rate” is a calculated approximation for function control of the system.
This determines the sensor that is used to measure the flow temperature.
Settings range: S1-S8, VFS1-2, active collector, active storage/ Default setting: S1
6.5.1.1 Flow Sensor (X)
This determines the sensor that is used to measure the return temperature.
Settings range: S1-S8, VFS1-2, Aktiver Collector, Active storage/ Default setting: S2
6.5.1.2 Return Sensor
Set the type of anti freeze used. If none is used, please set to 0.
Settings range: Ethylene, Propylene / Default setting: Propylene
6.5.1.3 Anti-Freeze Type
The amount of anti freeze agent in the system.
Settings range: 0-100% / Default setting: 45%
6.5.1.4 Glycol Perncentage