Technical Data PWM
Technical Data 0-10V
- 0-10V: 2V (20%) to 10V (100%)
- Designed for a load of 10K Ohm.
10V = 100% Speed
5V = 50% Speed
2V = 20% Speed
0V = Off
Useful Notes / Tips & Tricks
Instead of setting the flow rate for the system using a flow rate limiter, it is better to adjust the flow rate using the switch on the pump and by
means of the “max. speed” setting on the controller (see. “6.3.4. - max. speed” on page 32). This saves electricity!
The service values (see “8. - Service values” on page 49) include not only current measurement values and operating states, but also all of the set-
tings for the controller. Write down the service values at least once after commissioning has been successfully completed.
In the event of uncertainty as to the control response or malfunctions the service values are a proven and successful method for remote diagnosis.
Write down the service values (see “8. - Service values” on page 49.) at the time that the suspected malfunction occurs. Send the service value table
with a brief description of the error to the specialist or manufacturer.
In the programs with pool the charging of the pool, e.g. for winter operation, can be switched off using a simple function. To do this, simply press
and hold the “esc” key down for several seconds on the diagram/overview screen. A message appears on the display as soon as the pool is switched
off or when the pool is switched on again.
To protect against loss of data, record any analyses and data that are particularly important to you (see 2.) at regular intervals.