SunMaxx Solar LLC
Page 12 of 39
should be close to the latitude of the location.
All the piping should be properly supported according to plumbing code. These
supports must not compress the insulation.
Any structural element or fire rated assembly should not be reduced after penetration
during the installation. It will be up to local code to dictate exactly how this is done.
The outdoor pipes should be insulated with R6.6 insulation with thickness at or greater
than 1 inch. The indoor pipes should be insulated with R2.6 with thickness at least 1/4”.
4.5.11 Projected components need to be replaced
The glass vacuum tubes might need to be replaced if broken by unexpected hazards,
such as collision with a hard material. Please contact the installer to order replacement
parts. The battery of the temperature monitor needs to be replaced when the battery is
out. The battery can be purchased at store.
5. Installation of solar water heater
5.1. Frame installation drawing
(
Solar Water Heater for Flat Roof
)
1.rear pole 2.triangle plate 3.tank bracket 4.level bar 5.rear support bar
6.front support bar 7.front pole 8.tail stock 9.back box 10.feet
(
Solar Water Heater for Sloping Roof
)