The design and installation of systems shall not impair emergency movement of the
building occupa
nts.
.The installation shall:
. NOT IMPAIR ENCLOSURE FUNCTION
. NOT ALLOW VERMIN INTRUSION
.MEET APPLICABLE CODES AND NATIONAL ROOFING CONTRACTORS ASSOCIATION
PRACTICES
6. Pipeline installation
6.1 Plumbing system schematic map
ThemoPower-VTS15-FP and ThermoPower-VTS30-HP products are solar hot water
heater systems which pre-heat inlet water with solar energy prior to feeding into the
conventional hot water heater. It can be integrated with the existing gas, electric,
propane, or oil hot water heater by installing upstream of the existing hot water heater.
Food grade materials should be used for all water contact areas.
A mixing valve must be installed if the homeowner does not have one currently. Set the
output water temperature at a point of 48.9
o
C (120
o
F).
The tank upper temperature limit is 300°F and 130 psig. As the thermosiphon system
has no way to stop the operation of the solar collector, there should always be a T&P
relief valve installed to release some high temperature water out of the tank; then
mains water will charge the tank to keep the tank in normal working condition.
The T&P valve releases some water out of the tank when the temperature is more than
194°F, or the water pressure is above 58 psi to ensure the safety of the system.
The specification of the T&P R is,
Inlet:1/2 in tapered male thread
Outlet:1/2 in parallel female thread
Maximum opening temperature:90
℃
/99
℃
Rated working pressure: 0.4MPa/0.6MPa
Maximum working pressure
:
1.5MPa
If you are away from your home for a long time and the system will not be used
during that period, we recommend you drain down the system and close the inlet
valve to avoid overheating. In order to prolong the system’s life, cover the collector