Vacuum
P<0.005Pa
Heat Loss
<0.8W/
㎡
Insulation
Polyurethane,55mm
Stagnation Temperature
<220
℃
Maximum working temperature
90
℃
Maximum Working Pressure of all
circuits
0.6MPa
Working pressure
0.4MPa
Maximum wind and snow load
0.49kN/m²
Tilt Angle
45°
Inlet and Outlet
1/2inches
T&P Valve Port
1/2 inches
Frame
Aluminum Alloy
4.2 System Tolerance Information
Freeze tolerance limits are based upon an assumed set of environmental conditions.
Extended periods of cold weather, including ambient air temperatures above the
specified limit, may cause freezing in exposed parts of the system. It is the owner’s
responsibility to protect the system in accordance with the Supplier’s instructions if
the air temperature is anticipated to approach the specified freeze tolerance limit.
4.3 System start-up procedures
After the system installation, check there is no leakage in the system and follows the
following steps to start up the system.
Step 1: Connect Garden Pipe to Drain Valve V4, and keep V4 Open.
Step 2: Open the following valves: V0, V2, V4 and shut off the following valves: V1,
V3, and V5
Step 3: Keep the water running for 5 minutes to flash out the solder or stains after the
water from V4 is observed.
Step 4: Shut off V4 and Open V3, and the system is in normal operating status.