The inlet and outlet port size is 1/2” tube, you can choose the pipe size between the
water supply and water tank connections can be 1/2” or 3/4”. And the safety valve
size is also 1/2”. Make sure all the safety valves are in normal condition before
flushing the system.
The temperature monitor and sensor shall be installed suitably to ensure the system
can work normally. There are two recommended methods to install temperature sensor
into the inlet and outlet pipe.
Method 1, use a three way valve and sensor pocket to install the temperature sensor at
the inlet and outlet port of the water tank.
Fig1. sensor pocket
Fig2. the top end of the
sensor pocket
Fig3.
sensor
connect with three way
valve
It would be better to install the sensor at the inlet and outlet port of the tank to
measure the temperature accurately.
Method 2, if the sensor pocket is not available when install the system, you can
choose an easier method to install the temperature sensor.
step1. Put the temperature
sensor close to the inlet and
outlet copper pipe. Keep
them contact tightly.
Fig2. Use duct tape to fix
the sensor.
Fig3. Then insulate the
whole pipe with PU
foam.