background image

 

SunMaxx Solar

 | 

Flush Mounting

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

3e 

Step 4:

Mounting the collectors 

a.

 

Position panel(s) on the rails.  

b.

 

If there is more than one panel, loosely connect them together. Make sure to include the graphite washer. 

c.

 

Once the panel(s) are in the desired position, attach the adjustable clamping plate to the panel using the 

Hex bolts included on the ends of the collector. 

d.

 

Attach the adjustable clamping plate to the rail, using the M8x22mm bolts. 

e.

 

Make sure to return and tighten the connections between the panels. 

4b 

4a 

Summary of Contents for TitanPower Plus-SU2 Collector

Page 1: ...SunMaxx Solar Flush Mounting ConnectMaxx Mounting Systems Installation Instructions TitanPower Plus SU2 Collector Flush Mounting...

Page 2: ...outdoors Rinsing filling and maintenance During installation and setup of the collectors keep them covered to prevent damages Please consider the national rules and manufacturer instructions for the u...

Page 3: ...eld Attention Circumferential additional approximately 5 91 of space is needed Pressure Loss Tm 20 C Flow l h 0 50 100 150 200 250 Pressure Loss Pa 0 564 1168 1811 2493 3215 Number of Collectors Field...

Page 4: ...Screw M8x22 ConnectMaxx 18000305 End Cap PP 40x40mm ConnectMaxx 74010701 2120 Mounting Rail Medium 40x40 7ft length ConnectMaxx 74011003 Rail Connector Fixed for 40x40mm ConnectMaxx 74022601 Adjustab...

Page 5: ...e roof hook on the roof Loosen the shingle above the roof hook and temporarily set the flashing in place This is to make sure the placement of the roof hook is accommodating b Using the Simpson Strong...

Page 6: ...sliding channel is face up and the grooved channel is facing the roof hook Press the clamping plate into the grooved channels c Screw the M8 x 22mm socket bolt into the channel attaching the rail to t...

Page 7: ...SunMaxx Solar Flush Mounting 3b 3c 3d 3a...

Page 8: ...gether Make sure to include the graphite washer c Once the panel s are in the desired position attach the adjustable clamping plate to the panel using the Hex bolts included on the ends of the collect...

Page 9: ...e Universal Connect Set a Left to Right Piping from bottom left to top right b Right to Left Piping from bottom right to top left The Hot Supply from the collector should be the shortest pipe run 5a T...

Page 10: ...SunMaxx Solar Flush Mounting Bottom Left of Collector Bottom Right of Collector 5b Top Left of Collector Top Right of Collector Bottom Left of Collector Bottom Right of Collector...

Page 11: ...perature sensor well Insert temperature sensor and tighten the compression nut so that the sensor wire is sealed Contact Us Headquarters Sales Office 56 Broome Corp Pkwy Conklin NY 13748 Training Faci...