More About Workout Parameters
Field
Setting Range
Default
Value
Increment/
Decrement
Description
Time
0:00~ 99:00
00:00
± 1:00
1.When the display is 0:00, Time will
count up.
2.When the Time is 1:00-99:00, the time
will count down to 0.
Distance
0.00~999.0
0.00
±1.0
1.When the display is 0.0, Distance will
count up.
2.When the Distance is 1.0~999.0, it will
count down to 0.
Calories
0~9995
0
±5
1.When the display is 0, Calories will
count up.
2.When the Calories are 5~9995, it will
count down to 0.
Watt
45~250
100
±5
User can set watt value only in the Watt
control program.
Age
10~99
30
±1
Target HR will be based on Age. When
Heart Rate exceeds Target H.R, the
Heart Rate number will flash.
Pulse
60~220
90
±1
Setting Parameters for Target heart
rate.
PROGRAM OPERATION
:
Manual (P1)
Program profile
Setting Parameters for Manual
Select “
Manual
” using the UP or DOWN button, then press ENTER. The first parameter “TIME” will
flash so the value can be adjusted using the UP or DOWN buttons. Press the ENTER button to
save the value and move to the next parameter to be adjusted.
Note: If the user sets up the target time to workout, then the next parameter for Distance
cannot be adjusted.
Continue through all desired parameters, and press the START/STOP button to begin the workout.
Note: Once the workout parameter counts down to zero, it will beep and stop
the workout automatically. Press the START button
to continue the workout to reach the
unfinished workout parameter.