NOTE:
If you are unable to resolve an issue using the troubleshooting guide above,
please contact customer service at
support@sunnyhealthfitness.com
.
Console
displays
E04:
Incline failure
The
incline
motor
is
damaged OR the wire for
the incline motor is not
connected properly or has
become damaged
Reconnect or replace the
wire for the incline motor.
Replace the incline motor.
Console
displays
E05:
Current
overload
protection (Self Protecting
System)
The incoming voltage is
too low or too high. The
control board is damaged.
Restart
the
treadmill.
Check
the
incoming
voltage to ensure it’s
correct. Check the control
board, replace if damaged.
A moving part of the
treadmill is stuck and
therefore the motor is
unable to rotate properly.
Inspect moving parts of the
treadmill to ensure that
they
are
operating
correctly. Check the motor,
listen for strange noise and
check for a burning smell.
Replace
the
motor
if
necessary.
Console
displays
E08:
Control Board Abnormality
The control board is not
connected
Check
the
upper
and
middle wires to see if the
control board is connected.
If the wire has been
punctured or damaged,
you will need to replace it.
If the problem is not
rectified, you may need to
replace the control board.
23
Summary of Contents for SF-T7512
Page 4: ...EXPLODED DRAWING 3...