background image

 

------------------------------------------------------------------------------------------------------------------------------------------------------------------------- 

28 

SUNONWEALTH ELECTRIC MACHINE INDUSTRY CO., LTD. 

UFO 3 INSTALLATION (2019.12.23) V1 

 

Warranty 

 

Purchase Date

 

DD 

MM 

YY

 

Serial Number

 

 

Retailer's Stamp 

We offer 1 year warranty of our product starting from your 

purchase date.   

The following scenarios are excluded from our warranty 

service. Repairing request will be accepted, but the customer 

will be charge for cost and service fee. 

1. Damage of improper installation. 

2. Damage of retrofit. 

3. Damage of force majeure: Nature, actions of third parties 

4. Damage of misuse, abuse, accident. 

5. Damage of improper transportation. 

6. The warranty document, purchase date or purchase 

confirmation (like invoice) from authorized dealer cannot 

be provided by the customer. 

 

 

Summary of Contents for UFO3 BCEE1BA100A-01S

Page 1: ...TD UFO 3 INSTALLATION 2019 12 23 V1 UFO3 HVLS FAN 4 2 m 3 6 m 3 0 m 2 5 m 14 ft 12 ft 10 ft 8 ft Original Instructions BCEE1BA100A 01S BCEE1BA120A 01S BCEE1BA144A 01S BCEE1BA168A 01S BCNE1BA120A 01S BCNE1BA144A 01S BCNE1BA100A 01S BCNE1BA168A 01S ...

Page 2: ... switches to prevent power from being switched on accidentally When the circuit breaker cannot be locked securely fasten a prominent warning device such as a tag to the service panel 7 SUNON provides installation guide for mounting fans however it is the sole responsibility of the building owner and installer to ensure the safety of the mounting system that the building structure is sound and that...

Page 3: ... with the appliance 12 SUNON Fans product warranty will not cover equipment damage or failure that is caused by improper installation or use 13 If unusual oscillating movement is observed immediately stop using the ceiling fan and contact the manufacturer its service agent or suitably qualified persons 14 UFO ceiling fan controller is equipped with a memory function After disconnecting power it st...

Page 4: ...hts and interests please make sure that the deals records the purchase date dealer s name etc on the guarantee Table of Contents 1 Introduction 2 Product Specifications 3 Installation Precautions 4 The Placement Clearance between fan and obstructions 5 Inside the Box 6 Tools Required for Installation 7 Pre Installation Checklist 8 Installation Method 9 Wiring Diagram 10 Remote Control Operation In...

Page 5: ...gn brings excellent airflow to space We assure you this appliance will make your space cozier and occupant comfort in the near future Fan Outline D H1 H2 H3 H4 Model D A B H1 H2 H3 H4 BCEE1BA100A 01S BCNE1BA100A 01S 2 5m 8ft 350mm 1 1ft 200mm 0 65ft 643mm 2 1ft 840mm 2 8ft 1000mm 3 3ft 133mm 0 4ft BCEE1BA120A 01S BCNE1BA120A 01S 3 0m 10ft BCEE1BA144A 01S BCNE1BA144A 01S 3 6m 12ft BCEE1BA168A 01S B...

Page 6: ... 114 166 245 335 UFO3 HVLS Fan 3 m 10 ft Model BCEE1BA120A 01S BCNE1BA120A 01S Input Voltage VAC Input Frequency Hz Rated Power W Rated Current A Maximum RPM RPM Noise dB A 200 240 50 60 232 1 44 100 40 Button 1 2 3 4 5 6 Speed RPM 50 60 70 80 90 100 Power Consumption W 34 53 83 115 164 232 UFO3 HVLS Fan 3 6 m 12 ft Model BCEE1BA144A 01S BCNE1BA144A 01S Input Voltage VAC Input Frequency Hz Rated P...

Page 7: ...tage VAC Input Frequency Hz Rated Power W Rated Current A Maximum RPM RPM Noise dB A 200 240 50 60 171 1 1 56 40 Button 1 2 3 4 5 6 Speed RPM 30 35 40 45 50 56 Power Consumption W 27 43 64 90 120 171 Forward The ceiling fan should rotate counterclockwise Looking up from the ground Reverse The ceiling fan should rotate clockwise Looking up from the ground ...

Page 8: ...The HVLS fan model covered by the installation instructions must comply with this installation manual and all national local electrical codes to avoid personal injury or property damage 10 Please ensure that this application is equipped with AC single phase 200 240 V before installation 11 All fan parts must be 0 6 m 2 ft from all obstructions The fan installation area must be free of obstructions...

Page 9: ...r 17 Pleases see the manufacturer s requirements for the minimum clearance to combustibles 18 The fan inlet or other return air point that produces negative pressure should be bigger than 1 times the diameter of the ceiling fan This system will reduce the airflow of the HVLS fan 19 Proper systems orientation will provide an enhancement to the Indoor Air Quality and occupant comfort Please refer to...

Page 10: ...ment Clearance between fan and obstructions space from the lights at least 0 6 m away spacing between fans at least 2 5x diameter of the fans apart The tip of the airfoil need at least 0 84 m away from beam ceiling and no obstacles space from wall at least 0 6 m away 3 05 m 0 84 m 0 6 m 0 6 m ...

Page 11: ...er The distance between the center of the ceiling fan and HVAC equipment need to at least 2x diameter The HVLS fan position need to below the HVAC outlet The distance between the center of the ceiling fan and HVAC equipment need to at least 1 5x diameter The HVLS fan position need to above the HVAC outlet HVAC Diffuser HVAC Diffuser ...

Page 12: ...ke only can be used within the width of 100 300 mm B and thickness of 20 mm I beam Within the thickness of 14 mm t the yoke only need to use 1 yoke washer The thickness of 14 20 mm t the yoke need 2 washers We do NOT suggest to install the HVLS Fan on the fabricated I beam please consult with structural engineer to make sure your building is approved for fan installation I beam shim ...

Page 13: ...r 1 Remote Control 1 Extension Tube 1 Extension Tube Shield 2 Safety Cable 1 Wire Rope Clamp 20 Hardware and Bolt Kits Fixed angle mount bracket shim 2 I beam shim 4 I beam clamp 2 Winglet 7 Extension Tube clamp 2 Guy wire bracket 2 Turn buckle 4 Beam Clamp Set 4 Ferrite Bead Clamp 1 Earth Wire 1 Airfoil Box Anodized Aluminum Airfoils Airfoils 7 ...

Page 14: ...ical Installation Electrical Installation Standard wrench socket set Phillips screwdriver Standard Allen wrench set Flat head screwdriver Hydraulic cutter Multimeter Galvanized wire Ø4 mm Trim the wire length according to the situation Pair if 10 to 14 AWG strippers Torque wrench 50 300 kgf cm For inspection purpose Electronic level ...

Page 15: ...tance between the blades and other objects building structure should be at least 2 feet 0 6 meters Please refer to The Placement Clearance between fan and obstructions Page 9 The distance between the fan and other objects means the distance between the blade tips and the objects The center to center distance between two fans should be at least 2 5 times the diameter of the fans Please refer to The...

Page 16: ... 240 Kgf cm 2 Attach the fixed angle mount bracket to the yoke horizontally and tighten with 4 sets of Fixed angle mount bracket M10x35L 4 bolt kit Recommended Tightening Torque 24 N m 240 Kgf cm 3 Attach the Fixed angle mount bracket shims to the Fixed angle mount bracket and fixed them by Extension tube M10x70L 3 bolt kit on the top position as picture shows Recommended Tightening Torque 24 N m ...

Page 17: ... the extension tube clamp into the extension tube make sure the chamfer as picture shows is downward and tighten with 6 sets of extension tube clamp M8x 15L 6 bolt kit Recommended Tightening Torque 12 N m 120 kgf cm 6 Insert the motor tube in the extension tube clamp then take out the earth wire and guy wire bracket as picture shows to tighten with motor tube with 3 sets of M8x 55L 3 bolt kit Reco...

Page 18: ...s make sure the U shaped inside the wire rope clamp is tighten to the short side a Wire Rope Clamp 4 b Safety Cable 1 8 1 Through Earth Live and neutral wires into ferrite bead clamp and wrap a circle 8 2 Connecting the Earth Live and neutral wires with motor and mains power Please refer to Wiring Diagram Page 15 L Live wire N Neutral wire E Earth wire U Shaped Short side Long side Mains Power Saf...

Page 19: ...ide first with 4 sets of extension tube shied blot kit while installing on extension tube Recommended Tightening Torque 5 N m 50 Kgf cm 10 1 Prepare 4 guy wires with Ø4mm when installation The technician needs to prepare guy wire and tailor it according to the situation 10 2 Looking up from the bottom of ceiling fan the angle between each cable and I beam is recommended to be 45 degrees 10 3 The a...

Page 20: ...mp tightly 11 2 Tailor the guy wire according to the situation Guy Wire Bracket Recommended Tightening Torque 5 N m 50 Kgf cm Beam Clamp Set Guy Wire Bracket 4 8 12 1 Attach the beam clamps to the I beam and securely fasten to the proper position based on step 11 12 2 Pass the safety cable through the ring and secure with guy wire bracket Beam Clamp Set Recommended Tightening Torque 12 N m 120 Kgf...

Page 21: ...lance Repeat this step to complete 4 sets of wire rope bolt kit to secure the turnbuckle a Guy Wire Bracket 8 b Turnbuckle 4 Recommended Tightening Torque 5 N m 50 Kgf cm 14 Insert the winglet into the airfoil and tighten with 7 sets of winglets M6x35L 7 bolt kit as picture shows Recommended Tightening Torque 5 N m 50 Kgf cm 15 Insert the airfoil into the airfoil holder and tighten with 21 sets of...

Page 22: ...er installation UFO3 HVLS Fan installation should follow national electrical code and standard Requirements for Electrical Power This Appliance connecting to 200 240 voltage AC Please see the voltage sticker on this HVLS fan avoid any voltage changes in case of danger damage during installation Model Airfoil Dimension Input Power Source Rated Current BCEE1BA100A 01S BCNE1BA100A 01S 2 5 m 8 ft 200 ...

Page 23: ...North America GREEN BLACK WHITE Europe GREEN YELLOW BROWN BLUE Taiwan GREEN YELLOW BROWN BLUE Other GREEN YELLOW BROWN BLUE END USER FAN Live Wire Neutrul Wire Earth Wire WiringDiagram QF Circuit Breaker Recommend 20 A H Extension tube Notes A set of terminals can be connected to the flexible cord for fixed wiring For example crimped connector or other similar devices UFO 3 ...

Page 24: ...ssfully Press the button to switch the fan direction it will give 2 beeps after the fan receive successfully when the fan Reverse 2 long beep and the airflow move upwards Looking up from the ground the rotation is clockwise Forward 2 short beep and the airflow move downwards Looking up from the ground the rotation is counterclockwise Press these two buttons at same time to enter pairing process Af...

Page 25: ...stallation Remove the battery cover and install two AAA batteries Remove the batteries when not used a long time Please recycle the used batteries Operating Instructions 1 Make sure the fan blades are standstill before you turn on the fan every time 2 Press 0 to turn off the fan DO NOT touch the fan and blade until its standstill 3 Once you press any buttons the fan will receive the final order an...

Page 26: ...olved before reaching out the service Refer to the tips below before contacting Customer Service Symptom Possible Solutions Abnormal sound from the fan Airfoil noise occurs when airfoils are not tightened to the specified torque Turn off the fan power and then tighten the airfoil fasteners to 50 kgf cm If the abnormal sound still occurs please confirm if the airfoils are not contacting each other ...

Page 27: ...se a gentle cleaner or degreasing agent when dusting the motor DO NOT use chlorine based cleaning products in case the toxic fatal fumes exposure 6 Check all the connections such as safety cables mounting parts is tighten Also make sure the mounting system is securely tighten Any wobbling problems should not happen when you switch on the fan If any wobbling problem is noticed make sure the mountin...

Page 28: ...e excluded from our warranty service Repairing request will be accepted but the customer will be charge for cost and service fee 1 Damage of improper installation 2 Damage of retrofit 3 Damage of force majeure Nature actions of third parties 4 Damage of misuse abuse accident 5 Damage of improper transportation 6 The warranty document purchase date or purchase confirmation like invoice from authori...

Page 29: ...IC MACHINE INDUSTRY CO LTD UFO 3 INSTALLATION 2019 12 23 V1 Sunonwealth Electric Machine Industry Co Ltd 80673 No 30 Ln 296 Xinya Rd Qianzhen Dist Kaohsiung City 806 Taiwan R O C w w w s u n o n c o m E mail sunon sunon com ...

Reviews: