Installation & Operation Manual for the
Active Vibration Cancellation (AVC) System
7)
Display the integral constant of the temperature control loop
a)
Command:
KI<CR>
b)
Returns the integral constant of the temperature control loop.
8)
Set the integral constant of the temperature control loop
a)
Command:
KI=<VAL><CR>
b)
This command is User locked.
c)
<VAL>
is the user defined integral constant of the temperature control loop.
9)
Display the proportional constant of the temperature control loop
a)
Command:
KP<CR>
b)
Returns the proportional constant of the temperature control loop.
10)
Set the proportional constant of the temperature control loop
a)
Command:
KP=<VAL><CR>
b)
This command is User locked.
c)
<VAL>
is the user defined proportional constant of the temperature control loop.
11)
Display the current status of the LCD
a)
Command:
LCD<CR>
b)
Returns the current status of the LCD.
12)
Set the state of the LCD
a)
Command:
LCD=<VAL><CR>
b)
This command is User locked.
LCD states:
ON – LCD is regularly updated.
OFF – LCD is not updated.
KI
001.00000
KI=0.5
000.50000
KP
001.00000
KP=5
005.00000
LCD
OFF
LCD=ON
ON