5.0  Module Mounting   

The SunPower Limited Warranty for PV Modules is contingent upon modules 

being mounted in accordance with the requirements described in this section. 

 

5.1 Site Considerations

 

SunPower modules should be mounted in locations that meet the following 

requirements: 

 

Operating Temperature: All SunPower modules must be mounted in 

environments that ensure SunPower modules will operate within the following 

maximum and minimum operating temperatures: 

 

Maximum Operating Temperature 

+90   Celsius, +194   Fahrenheit 

Minimum Operating Temperature 

-40   Celsius, -40   Fahrenheit 

 

Care should be taken to provide adequate ventilation behind the modules, 

especially in hot environments. 

 

Design Strength:  SunPower modules are designed to meet a maximum 

positive (or upward, e.g. wind) and negative (or downward, e.g. static load) 

design pressure of 50 lb/ft² when mounted in one of the mounting 

configurations specified in Section 5.2.   A design strength of 50 lb/ft² 

corresponds approximately to a wind speed of 125 mph.  

 

When mounting modules in snow-prone or high-wind environments, special 

care should be taken to mount the modules in a manner that provides 

sufficient design strength while meeting local code requirements. 

 

Excluded Operating Environments:  Certain operating environments are not 

recommended for SunPower modules and are excluded from the SunPower 

Limited Warranty for these modules. 

 

No SunPower module should be mounted at a site where it may be subject to 

direct contact with salt water. 

 

5.2 Mounting Configurations 

Modules may be mounted at any angle, from horizontal to vertical. Select the 

appropriate orientation to maximize sunlight exposure.  Specific information on 

module dimensions and the location of mounting and grounding holes is 

provided below (Figures 3 and 4).  

 

In order to prevent water from entering the junction box, which could present a 

safety hazard, modules should not be mounted such that the front/top glass 

faces downward (e.g.,  on a tracking structure that positions the modules with 

the junction box facing skyward during sleep mode).  

 

Clearance between the module frames and structure or ground is required to 

prevent wiring damage and allows air to circulate behind the module.  

 

The module is only UL Listed for use when its factory frame is fully intact.  Do 

not remove or alter the module frame. Creating additional mounting holes may 

damage the module and reduce the strength of the frame.   

 

Modules may be mounted using the following methods only: 

 

1)  Frame Holes: Secure the module to the structure using the factory 

mounting holes. Four ¼” stainless steel bolts, with nuts, washers, and 

lock washers are recommended per module. Refer to Figure 3 for the 

module dimensions and hole locations. This method has been certified 

by a third-party organization according to UL 1703.  

 

2)  Pressure Clamps or Clips: Mount the module with the clips on the side 

frame of the module. The side frames are attached to the longer sides of 

the module.  The centerline of the clips should be 6 -15 from the end of 

the side frame.  Installers should ensure the clamps are of sufficient 

strength to allow for the maximum design pressure of the module. Clips 

and clamps are not provided by SunPower.    

 

3) 

End Mount: End mounting is the capture mounting of the length of the 

module’s end frame to a supporting rail. The end frames are on the 

shorter dimensions of the module.  The end-mounting rail and clips or 

clamps must be of sufficient strength to allow for the maximum design 

pressure of the module. Verify this capacity with the mounting system 

vendor before installation.

 

 

 

6.0  Maintenance  

Inspect all modules annually for safe electrical connections, sound mechanical 

connection, and freedom from corrosion. Periodically clean the module surface 

with water and a soft cloth or sponge. Fingerprints may be removed with 

standard glass cleaner. Do not use harsh cleaning materials such as scouring 

powder, steel wool, scrapers, blades, or other sharp instruments to clean the 

glass surface of the module. Use of such materials will invalidate the product 

warranty. 

 

B

ØAA

(GROUND)

ØAA

(GROUND)

A

G

H

ØBB

E

C

F

D

ØAA

(GROUND)

 

Figure 3 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 4 

 

MODEL FORMAT 

DIMENSION 

72-Cell Models 

 (mm, in) 

798 (31.42) 

1559 (61.39) 

915 (36.02) 

332 (12.69) 

754 (29.69) 

1200 (47.24) 

180 (7.04) 

46 (1.81) 

ØAA (Ground) 

4X 4.2 (0.17) 

ØBB 

4X 6.6 (0.26) 