background image

Identification: 

 

 

 

Input:

 

1. Input range: 

SPR-2326A6: 90~132VAC / 180~264VAC auto sensing 

SPR-2326P6: Universal full range AC 90V ~ 264V. 

2. Inrush current: When turn on input power source, there is peak current (inrush 

current) running through filter capacitor of power supply. During power supply 

operating, it is important not to turn off input power source and then immediately 

turn on it again, otherwise, it may shorten power supply’s life. 

 

Output: 

SPR-2326A6 / SPR-2326P6 has six outputs.   

Output of +3.3V plus +5V is 150W max, and output of –5V plus –12V is 12W max. 

Total output is 320W max

The loadings of each output are adjustable inside specified range, however, total 

output should not exceed maximum rating. 

Ex1: (Dual modules): 

False!!

 

Output V1 V2 V3 V4 V5 V6 

V3.3V +5V +12V -5V -12V 

+5Vsb 

Load 15A 

30A 

20A 

0.5A 

1.0A 

4A 

Output 199.5W 

240W 

14.5W 20W 

Total output 

474W, OVER!! 

 

Ex2: (Dual modules): 

!

 

 

Output V1 V2 V3 V4 V5 V6 

V3.3V +5V +12V -5V -12V 

+5Vsb 

Load 15A 

20.1A 

11.5A 

0.5A 

0.8A 

4A 

Output 150W 

138W 

12W 20W 

Total output 

320W, OK!! 

Ex3: (Dual modules): 

!

 

 

Output V1 V2 V3 V4 V5 V6 

V3.3V +5V +12V -5V -12V 

+5Vsb 

Load 10A 

3A 

20A 

0A 1A 4A 

Output 48W 

240W 

12W 

20W 

Total output 

320W, OK!! 

 

Ex4: (Dual modules): 

!

 

 

Output V1 V2 V3 V4 V5 V6 

V3.3V +5V +12V -5V -12V 

+5Vsb 

Load 19.7A 

3A 20A 0A 0A 0A 

Output 80W 

240W ---  --- 

Total output 

320W, OK!! 

For output specification, please refer to the label on the product or visit 

www.sunpower.com.tw

 for newly update data.

 

 

 

 

Protection: 

1. Short circuit protection: When circuit shorted, power supply will shutdown and 

latch. 

2. Over load protection: When over 105% ~ 150% of rated loading, power supply will 

shutdown and latch   

3. Over voltage protection: When output voltage exceeds rated range, power will shut 

down and latch. 

 

PS-ON signal: To switch ON/OFF power supply 

 

Logic State 

Function 

Input Voltage 

PS-ON = Hi 

To switch Off P/S  PS-ON > 2V 

PS-ON = Low  To switch On P/S  PS-ON < 0.8V 

 

Power fail alarm: 

When either power module fail or turn off, buzzer will beep, and 

TTL signal will be low. 

 

Fan fail alarm: 

When either power module fan fail, buzzer will beep, and TTL signal 

will be low. 

 

Safety terms:

 

 

1. The voltage running through primary circuit could up to 2~4 times of AC input 

voltage. It is forbidden for non-technicians to open the case. Contact your local 

dealer for technical support if needed.   

2. The temperature inside power supply may exceed 85

  during full loading, so it is 

dangerous to touch power supply at this time. Be sure to keep a proper distance 

between power supply and combustible material. 

 

Trouble Shooting: 

1.  Buzzer beeping & power fail LED blinking: 

(1) Only one module inside power set? 

In normal condition, both modules should be inserted into power set. If there is 

only one power module work in power set, buzzer will beep and power fail LED 

will blink.   

(2) Both modules is inserted in power set? 

Check 

Module Ok Indicator

 on the front of power supply (

see 

Identification

). If the LED indicator is out of light, check whether power module 

is well mounting, and whether AC power source inlet is well connected. If all well 

done, and LED indicator isn’t lighted, it means this module is in trouble. Replace 

a new one or contact your dealer for repairing.. 

 

2. Buzzer beeping & all indicator LED at normal condition: 

    Check each module’s fan. If the fan stops work, repair it or replace a new one. 

 

3. The whole power set couldn’t work? 

(1) Check whether it is well mounted.   

(2) Check whether AC power cord well connected.   

(3) Check whether PS-ON is pulled low. 

 

4. A sudden interrupt during normal working? 

(1) Check whether it is over rated loading. If so, reduce loading. 

(2) Check whether it is over rated voltage. If so, contact your dealer for help. 

(3) Check whether it is short circuit. If so, remove it. 

(4) Check whether it is over temperature. If the environmental temperature is over 

power supply’s working temperature range (0~70

), enforce air convection. (Over 

temperature protection is an optional function.) 

 

If all of the above items were checked and power supply still cannot function normally, 

please contact your local dealer for support or e-mail us: service@sunpower.com.tw. 

 
 
 
 
 
 
 
 
 
 
 
SUNPOWER TECHNOLOGY CORP. operates a policy of continuous development. Therefore, 
we reserve the right to make changes and improvements to any of the products described in 
this guide without prior notice.              
© SUNPOWER TECHNOLOGY CORP. All right reserved. 

URL: http://www.sunpower.com.tw

 

July 9, 2003  

 

 

Power ON/OFF switch

Buzzer reset button 

Bottom module ok indicator 

Top module ok indicator 

Reviews: