MAXEON SOLAR TECHNOLOGIES, LTD.
537620 Rev.F
©2022 Maxeon Solar Technologies, Ltd. All rights reserved. Specifications included in this document are subject to change without notice.
8
AC Electrical Characteristics:
AC
Ratings
AC values @ STC
Operating Limits
Model
AC Voltage
Output
(nom., V)
AC Max.
Cont.
Output
Curr. (A)
Max.
Series
Fuse
(A)
AC Max.
Cont.
Output
Power, W
or VA
AC Peak
Output
Power
(W) or VA
Freq. (nom.,
Hz)
Extended
Frequency
Range
(Hz)
AC Short Circuit
Fault Current
Over 3 Cycles
(A rms)
Overvolta
ge Class
AC Port
AC Port
Backfeed
Current
(mA)
Power
Factor
Setting
Power Factor
(adjustable)
lead. / lag.
Max. Units per Branch
(Europe – Australia)
SPR-MAX6-450-E3-AC
219-264
1.52
20
349
366
50
45-55
5.8
III
18
1.0
0.8 / 0.8
10 - 11
SPR-MAX6-445-E3-AC
219-264
1.52
20
349
366
50
45-55
5.8
III
18
1.0
0.8 / 0.8
10 - 11
SPR-MAX6-440-E3-AC
219-264
1.52
20
349
366
50
45-55
5.8
III
18
1.0
0.8 / 0.8
10 - 11
SPR-MAX6-435-E3-AC
219-264
1.52
20
349
366
50
45-55
5.8
III
18
1.0
0.8 / 0.8
10 - 11
SPR-MAX6-430-E3-AC
219-264
1.52
20
349
366
50
45-55
5.8
III
18
1.0
0.8 / 0.8
10 - 11
SPR-MAX6-425-E3-AC
219-264
1.52
20
349
366
50
45-55
5.8
III
18
1.0
0.8 / 0.8
10 - 11
SPR-MAX6-420-E3-AC
219-264
1.52
20
349
366
50
45-55
5.8
III
18
1.0
0.8 / 0.8
10 - 11
SPR-MAX6-430-BLK-E3-AC 219-264
1.52
20
349
366
50
45-55
5.8
III
18
1.0
0.8 / 0.8
10 - 11
SPR-MAX6-425-BLK-E3-AC 219-264
1.52
20
349
366
50
45-55
5.8
III
18
1.0
0.8 / 0.8
10 - 11
SPR-MAX6-420-BLK-E3-AC 219-264
1.52
20
349
366
50
45-55
5.8
III
18
1.0
0.8 / 0.8
10 - 11
SPR-MAX6-415-BLK-E3-AC 219-264
1.52
20
349
366
50
45-55
5.8
III
18
1.0
0.8 / 0.8
10 - 11
SPR-MAX6-410-BLK-E3-AC 219-264
1.52
20
349
366
50
45-55
5.8
III
18
1.0
0.8 / 0.8
10 - 11
SPR-MAX6-405-BLK-E3-AC 219-264
1.52
20
349
366
50
45-55
5.8
III
18
1.0
0.8 / 0.8
10 - 11
SPR-MAX6-400-BLK-E3-AC 219-264
1.52
20
349
366
50
45-55
5.8
III
18
1.0
0.8 / 0.8
10 - 11
SPR-MAX5-420-E3-AC
219-264
1.52
20
349
366
50
45-55
5.8
III
18
1.0
0.8 / 0.8
10 - 11
SPR-MAX5-415-E3-AC 219-264
1.52 20 349
366
50 45-55 5.8
III 18
1.0
0.8 / 0.8
10 - 11
SPR-MAX5-410-E3-AC 219-264
1.52 20 349
366
50 45-55 5.8
III 18
1.0
0.8 / 0.8
10 -11
SPR-MAX5-400-E3-AC 219-264
1.52 20 349
366
50 45-55 5.8
III 18
1.0
0.8 / 0.8
10 - 11
SPR-MAX5-390-E3-AC
219-264
1.52
20
349
366
50
45-55
5.8
III
18
1.0
0.8 / 0.8
10 - 11
SPR-P3-385-BLK-E3-AC
219-264
1.52
20
349
366
50
45-55
5.8
III
18
1.0
0.8 / 0.8
10 -11
SPR-P3-380-BLK-E3-AC
219-264
1.52
20
349
366
50
45-55
5.8
III
18
1.0
0.8 / 0.8
10 - 11
SPR-P3-375-BLK-E3-AC
219-264
1.52
20
349
366
50
45-55
5.8
III
18
1.0
0.8 / 0.8
10 - 11
SPR-P3-370-BLK-E3-AC
219-264
1.52
20
349
366
50
45-55
5.8
III
18
1.0
0.8 / 0.8
10 - 11
Please refer to the module datasheet for the AC electrical characteristic
Table 3. Module Frame Details
Platform
Module mounting and ground hole detail
Frame Profile
MAX6 RES AC GENERATION 5.2 FRAME MODULES
Residential
Modules
SIDE FRAME PROFILE
END FRAME PROFILE
382.70 mm
249 mm
Mounng Holes
4X Ø 6.8mm
1100 mm
1872 mm
1032 mm
4X Ø 4.2mm
Ground Holes
40 mm
32
40
24
40