SPS-360P-xx Series
Copy Right Sunpower Technology Corp. 2009, All Rights Reserved. SPS-360P-xx Rev 1.1
Specifications subject to change without notice. RS-190014 JUL-28-2021
QR0405-1 Rev,:1.0
Features:
*
Altitude during operation up to 16404ft ( 5000m )
*
Remote control ON/OFF Type Optional:
*
Universal AC input with active PFC circuit, P.F.>0.95
①
Standard Type SPS-360P-xx
*
Power ON with LED indicator
②
Reverse Type SPS-360P-xxR (has MOQ required)
*
Built in EMI filter, low ripple noise
*
100% full load burn-in test
*
Over voltage
、
over load
&
short circuit protection
*
UL, cUL, CB, CE approved
*
Over temperature protection
*
3 years warranty
*
Output voltage
±
10% adjustment
*
Output voltage remote sense
Specification:
INPUT
Voltage
85V ~ 264VAC universal full range or 120V ~ 375VDC.
Frequency
47 ---- 63 Hz
Current
<4.8A @100V AC input, full load condition
Inrush Current(TYP.)
35A@115V , 70A@230V AC input. Cold start at 25
℃
ambient
Leakage Current
<1.5mA@264V AC input
Power Factor
PF
>
0.95
OUTPUT
MODEL No.
SPS-360P-05 SPS-360P-12 SPS-360P-15 SPS-360P-24 SPS-360P-27 SPS-360P-30
SPS-360P-48
Voltage
5V
12V
15V
24V
27V
30V
48V
Min Load
0A
0A
0A
0A
0A
0A
0A
Max Load
50A
30A
24A
15A
13.4A
12A
7.6A
Output Tolerance
±2%
±1%
±1%
±1%
±1%
±1%
±1%
Ripple Noise MAX.
150mV
150mV
150mV
200mV
200mV
250mV
250mV
Efficiency (TYP.)
85%
89%
89%
89%
89%
89%
90%
Output MAX.
250W
360W
360W
360W
361.8W
360W
364.8W
PROTECTION
Over Voltage
5.8V~7.0V
13.8V~16.8V
17.3V~21.0V
27.6V~33.6V
31.1V~37.8V
34.5V~42.0V
55.2V~67.2V
Shutdown and latch off, recover after re-start up.
Over Load
&
Short Circuit
When power supply over 105%~ 150% max load or short circuit acted, power supply will be c
onstant current
limiting
and recover automatically after the fault is removed.
Over Temperature
Over 75
℃
±
5
℃
Shutdown and latch off, recover after re-start up
ELEC. CHAR.
Rise time
<20mS
Hold up time
>12mS@230V, full load condition
Setup time (TYP)
<3.0S@115VAC , <1.5S@230VAC
Remote sensing
(RS+, RS-).
Remote Control
RC+/RC-: Standard Type 0~0.8V= Power On; 4~10V= Power Off
;
Reverse Type 0~0.8V= Power Off; 4~10V= Power On
ENVIRONMENT
Temperature
Operating: -20 ~ +70
℃
; De-rating: 50 ~ 70
℃
: 2.5%/
℃
; Storage: -40 ~ +85
℃
Humidity
Operating: 20% ~ 90% RH (non condensing) ; Storage: 10% ~ 95% RH (non condensing)
SAFETY
Withstand voltage
I/P-O/P:3KVAC, I/P-FG:1.8KVAC, O/P-FG:0.5KVAC, 1minute
Isolation resistance
I/P-O/P, I/P-FG, O/P-FG
>
100MΩ/500VDC at 25
℃
/ 70% RH
Safety standard
UL 62368-1, 2
nd
Edition, 2014-12-01,
CAN/
CSA C22.2 No.62368-1-14, 2
nd
Edition, 2014-12, IEC 62368-1:2014
EMC
EMI
Test Items
Standard
Test Level
Conducted
EN 55032
Class B
Radiated
EN 55032
Class B
Harmonic
EN 61000-3-2
Class D
Voltage Flicker
EN 61000-3-3
---
EMS
Test Items
Standard
Test Level
ESD
EN 61000-4-2
Level 3, 8KV air
;
Level 2, 4KV contact
Radiated
EN 61000-4-3
Level 2, 3V/m
EFT / Burst
EN 61000-4-4
Level 2, 1KV
Surge
EN 61000-4-5
Level 3, 2KV/Line-Eatth , 1KV/Line-Line
Conducted
EN 61000-4-6
Level 2, 3V
Magnetic Field
EN 61000-4-8
Level 2, 3A/m
Voltage Dips and Interruptions
EN 61000-4-11
>95% dip 0.5 period, 30% dip 25 periods
>95% interruptions 250 periods
OTHERS
Cooling
Forced airflow cooling with DC fan, the fan will be active when internal temperature
over 40
℃
.
M.T.B.F.
144.6 K hours
Dimension
198 x 99 x 38
㎜
(L*W*H)
Packing
N.W.: 0.727Kg / 1pc; 18pcs / 1.38 CUFT / 1 CTN
NOTE
All measurements which not mentioned are based on 230VAC input,
output Max
at ambient 25
℃
/ 70%RH
Output tolerance included set up voltage, line regulation and load regulation.
Ripple & noise are measured at 100
〜
254VAC input with 10
〜
50
℃
condition and 20MHz of bandwidth by using a 10
〞〜
15
〞
twisted pair-wire terminated
with a 0.1uF & a 47uF parallel capacitor.
The operating temperature shall follow the de-rating curve in spec
The output load may be requested for decreasing as de-rating curve in spec when low input voltage is under 100VAC..
The power supply is considered a component of end-equipment. The end-equipment must be re-confirmed whether comply with EMC directives.
360W, Single Output
198 x 99 x 38 mm
7.8 x 3.9 x 1.5 inch
Active P.F.C Function
C
B