B. Din rail mounting:

 

(contact your dealer for Din Rail brackets if needed) 

 

2-M

3*

4

2-M3*

5

60

-4

75

-07

9R

60-4

75-

076R

 

Grounding : 

thicker & short cable to connect between the Ground of the S.P.S.         

& rack, to prevent noise & leakage safety. 

L

N

PE

-V

+V

EQUIPMENT

CASE

 

 

 

 

 

 

 

 

 

Connection: 

 

 

 

 

 

 

 

L

OUT

IN

NP

E

-V

+

V

AD

J

V

-V

+V

LOAD

Power Source

AC/DC

 

Safety terms:

 

 

1. The Y capacitor inside power supply could deliver leakage current. When multiple 

power supplies work in parallel or in series, the leakage current will increase to cause 

the possibility of getting electric shock. Make sure ground wire is thick enough to 

prevent the danger.   

2. For AC input switching power supplies, the voltage running through primary circuit could 

up to 2~4 times of AC input voltage. It is forbidden for non-technicians to open the 

case. Contact your local dealer for technical support if needed.   

3. The temperature inside power supply may exceed 

85

(185

) during full loading, so it 

is dangerous to touch power supply at this time. Be sure to keep a proper distance 

between power supply and combustible material. 

 

Trouble Shooting: 

If power supply couldn't work properly, please turn off input power SW, and check the 

following steps: 

1. Check all the connections (pin in/out correct? polarity correct? etc.) 

2. Does terminal well connected? If not, reconnect it, and then turn on input power source 

again. 

3. Check load current. If over loaded, decrease loading, and then turn on input power 

source again. (Rated load current show on label) 

4. If there comes a sudden output interruption during adjusting VR, please turn VR to the 

middle value, and then turn on AC power again. 

5. If there is a temporary working followed by power supply shut down, it may cause by a 

higher inrush current requirement of the system. Replace a higher output power supply 

to meet the system’s requirement. 

6. If environmental temperature gets too low or too high? 

(1) If the environmental temperature lower than

 -20

(-4

, take either of the 

following steps:   

a. Use heater to warm up the environment; or, b. Reduce loading. 

(2) If environmental temperature higher than 

50

(122

)

, use extra cooling fans to 

enforce air convection, or reduce loading. (Refer to related specification) 

7. If the fuse inside power supply melted, there must be something function abnormally. 

Find out the abnormal cause and remove it; and then replace a new fuse. Make sure 
the new fuse’s spec must be same as the original. 

 

 
If all of the above items were checked and power supply still cannot 

function normally, please contact your local dealer for support or 
e-mail us: 

service@sunpower.com.tw

. Also,for input / output

 

Specification,please visit www.sunpower.com.tw. 
 
 
 
 
 
 
 
 
 
 
 

SUNPOWER TECHNOLOGY CORP. operates a policy of continuous development. Therefore, we 
reserve the right to make changes and improvements to any of the products described in this guide 
without prior notice.                           
© SUNPOWER TECHNOLOGY CORP. All right reserved. 
 

URL: http://www.sunpower.com.tw

 

April 3, 2009  

 

 

VR1 for adjusting output voltage. 
If there comes a sudden output 

interruption during adjusting VR, 

please turn VR1 to the middle 