3. c)
Installation: two systems on ground
.
Add-on kit (part # SQ-ADDON) is required.
Diagram Step 3c
•
Apply Teflon tape to threads of all the caps (
SK-FTG-F
) See Fig 3a-1
•
Thread all the caps into the panels as per Diagram Step 3c. Do not over tighten. See Fig 3a-2
•
Put "O" rings (
SK-FTG-I
) on two combination adapters (
SK-FTG-D
) See Fig 3a-3. You will only need
2 combination adapters for this type of installation.
•
Thread both combination adapters into the panels as per diagram Step 3c. Do not over tighten. See Fig 3a-4
•
Push the rubber hose (
SK-FTG-J
) over the panel header as per diagram Step 3c. Slide a metal collar
(
SK-FTG-L
) onto the rubber hose. Place metal collar
1
/
4
" from edge and tighten collar with screwdriver.
See Fig 3a-5. Repeat for 2
nd
system.
•
Slide another metal collar onto the rubber hose. Connect the 2 panels together by pushing the rubber hose
over the second panel header. Tighten metal collar to secure assembly. See Fig 3a-6. Repeat for 2
nd
system.
•
Install Add-on kit (
SQ-ADDON)
between two sets of panels (sold separately)
Note: A maximum of 6 2ft panels (3 systems) may be plumbed in series