background image

Model # SQ-2220-DLX

INSTALLATION & OPERATION

MANUAL

Read all the instructions before installing your solar heating system.

Summary of Contents for SQ-2220-DLX

Page 1: ...Model SQ 2220 DLX INSTALLATION OPERATION MANUAL Read all the instructions before installing your solar heating system...

Page 2: ...m your pool or one story up then your pump may need to be 1HP or more Where can the solar panel be placed The solar panel can be placed on the ground Avoid placing in high traffic areas as it is not r...

Page 3: ...ated metal strap 15 BOLT Z Lag bolt 2 Optional parts Roof Mounting Kit SQ RMK5 High Wind Roof Mounting Kit SQ HWK A Roof mounting kit is already included with your SunQuest For high wind areas to be u...

Page 4: ...escription 1 SK FTG A Threaded 2 way valve 4 SK FTG K Rubber hose 3 75 2 SK FTG B Threaded nipple 8 SK FTG L Metal collar Hose clamp 2 SK FTG C Threaded tee 1 SK VRV Vacuum Relief Valve 4 SK FTG D Thr...

Page 5: ...Thread both ribbed adapters into the panels as per Diagram Step 3a Do not over tighten See Fig 3a 6 Apply Teflon to threads of by pass valve SK INT V Screw side of valve with handle into the panel as...

Page 6: ...er tighten See Fig 3a 4 OR use adapters that fit best with your existing hoses Apply Teflon tape to threads of ribbed adapter SK FTG P See Fig 3a 5 Thread both ribbed adapters into the panels as per D...

Page 7: ...FTG L onto the rubber hose Place metal collar 1 4 from edge and tighten collar with screwdriver See Fig 3a 10 Repeat for other end of panel Slide another metal collar onto the rubber hose Connect the...

Page 8: ...le piping to connect panels to your pump then put O rings SK FTG I on both combination adapters SK FTG D See Fig 3a 3 Thread both combination adapters into the panels as per Diagram Step 3d See Fig 3a...

Page 9: ...t SK FTG K to connect the two set together as per Diagram Step 3d Install mounting kits as per instructions included with them Panels must be installed with a slight slope minimum 2 inch per 10 feet t...

Page 10: ...htened Unblock the inlet and outlet of your pool 5 Make sure the valve on the integrated diverter is on the open position See Fig C1 1 Valve in the open position Valve in the closed position Solar hea...

Page 11: ...plied and connect it to the last open end of the diverter kit Place metal collar and tighten Connect the other end of the hose to your pool inlet Place metal collar and tighten See diagram C 2 7 Make...

Page 12: ...t all your piping in drained 4 Run you feed and return PVC piping from your pool to your solar panels Make sure piping is installed in such a way to allow proper drainage 5 Make sure that your piping...

Page 13: ...d turn your by bass valve in such a way to allow the water from your panels to drain Wait half an hour for panels to drain Unscrew the Vacuum Relief Valve or the Threaded cap at the top of the solar s...

Page 14: ...logies Inc Claims will not be accepted for a solar panel s damage in transit unless damage to shipping container is noted at time of delivery on the transport company s delivery bill Sunsolar Energy T...

Reviews: