IP Ping Testing
View information on received errors, and presents frame statistics.
The top line of the results tables shows you the port number and the type of test the
statistics are for (e.g: PING or TRACEROUTE).
Both the specific count of the error and the average rate at which the error was
received may be displayed for each type of error. Frame statistics are shown for both
the transmit direction and the receive direction, as appropriate.
For both the Transmit and Receive directions, view the Total number of frames
transmitted/received, and the Current, Minimum, Maximum and Average Frame
Rates, as well as the Current, Minimum, Maximum and Average Data Rate. Results
are aggregate totals since the beginning of the test, for all test streams and live
traffic.
Statistic Details
Total Frames
Number of received/transmitted frames.
Total Bytes
Number of received/transmitted bytes.
Frame Rate
Transmitted and received frames per second.
Frame Rate Current
: Current rate at which frames are
being TX and RX at
Frame Rate Average
: Average transmitted and received
frames per second over the duration of the test.
Frame Rate Minimum
: Minimum
TX and RX frames per
second since the beginning of the test.
Frame Rate Maximum
: Maximum TX and RX frames per
second since the beginning of the test.
Utilization
Percentage of bandwidth in use:
Current
,
Maximum
,
Minimum
, and
Average
usages.
Line Rate
Transmitted bit rate, based on the current utilization.
Data Rate
Transmitted bit rate of the Ethernet frames, ignoring the
frame gap, preamble, and SFD. The data rate is always less
than the line rate.
Frame Size
Under 64
Bytes
Number of undersized/fragmented frames with a length of
less than 64 bytes.
Some VLAN and MPLS frames may be undersized even if
they fall within standard Ethernet frame sizes. For example,
a 64-byte frame with VLAN is too short—the length must be
at least 68 bytes.
•
For Unframed tests, only Bit Errors are reported.
FS 64 bytes
Count of frames with a length of 64 bytes.
FS 65-127
Count of frames with a length of 65-127 bytes.
FS 128-255
bytes
Count of frames with a length of 128-255 bytes.
FS 256-511
Count of frames with a length of 256-511 bytes.
FS 512-1023
Count of frames with a length of 512-1023 bytes.
FS 1024-
1518
Count of frames with a length of 1024-1518 bytes.
FS Over 1518
Count of jumbo frames with a length of 1519 or more bytes.
Test Frames
View statistics on frames matching the stream table.
117
Summary of Contents for XTT 5000
Page 1: ...XTT 5000 User s Manual...
Page 2: ......
Page 6: ......
Page 36: ......
Page 55: ...Throughput Testing L2 BERT Diagram Home Layer 2 BERT Where do you want to go next Home 49...
Page 58: ...XTT 5000 User s Manual Throughput Stream Results Throughput Test Setup Working Desktop Home 52...
Page 61: ...Throughput Testing Home 55...
Page 67: ...Throughput Testing Throughput Aggregate Results Throughput Stream Results Home 61...
Page 81: ...Throughput Testing Working Desktop Home 75...
Page 83: ...Throughput Testing Home 77...
Page 116: ......
Page 142: ......
Page 147: ...Save Features 141 RFC2544 NE Applications IP Test Setup Monitor Setup Loopback Test Setup Home...
Page 148: ......
Page 172: ......