Page 10
5.6
S
EASONAL
T
ILT OF THE
S
OLAR
A
RRAY
The sun is highest in the sky during the summer and lowest in winter. To maximize pumping during
both seasons, adjust the tilt angle periodically. Nearly all currently manufactured mounting racks
can be adjusted. It is sufficient to perform the adjustment only twice per year, at the spring and
autumn equinoxes, to the angles indicated below. See
Figure 5-2 Solar Array Tilt Angles by Latitude
.
If season adjustments are unwanted or unnecessary, set the tilt angle to the latitude of the pump
location, as a compromise. Do not set the array absolutely horizontal, or dust and debris will
accumulate.
Ideal angles are: Summer optimum = latitude -15° Winter optimum = la15°
FIGURE
5-2
S
OLAR
A
RRAY
T
ILT
A
NGLES BY
L
ATITUDE
Location
Latitude
Summer Tilt (-15°)
Winter Tilt (+15°)
Year-Round Tilt
Southern Canada
50°
35°
65°
50°
Upper Third of US
45°
30°
60°
45°
Middle Third of US
40
°
25°
55°
40°
Lower Third of US
35°
20°
50°
35°
Central Mexico
20°
5°
35°
20°
For additional tilt angles not listed, please consult the Mounting Rack Manual or Authorized SunRotor
®
Dealer
5.7
S
OLAR
A
RRAY
W
IRING
W
ARNING
:
Photovoltaic arrays generate hazardous voltages. A 48 Volt (nominal) array
can generate nearly 100 volts when disconnected from load. All wiring
MUST
be done
by qualified personnel, in compliance with local, state, and national electrical codes.
To prevent shock hazard while working on array wiring, leave one wire disconnected
between two modules to break the circuit, or cover array to shade it.
A
TTENTION
:
Wiring the panels in the wrong configuration (series or parallel) can damage
the controller. Be certain of the wiring configuration (See
Figure 5-3 Solar Panel Wiring
Diagram
for examples) prior to connecting the array to the controller. Additionally, it is
recommended to cover or shade the panels when connecting them to the controller. This
prevents electrical discharge from damaging the equipment. Any damage caused by disregarding
these warnings will
NOT
be covered under the warranty.
If the system uses a single panel, simply plug the MC4 connectors on the solar panel to the male and
female connectors on the controller; however, if more power or voltage is needed to meet the pump
requirements, multiple panels will have to be wired in either series, parallel, or a combined
series/parallel configuration. Examples are provided below to better explain the differences between
parallel and series.