FIGURE
7-1
W
IRE
S
PLICE
D
IAGRAM
7.2
I
NSTALLING THE
C
HECK
V
ALVE
All SunRotor
®
solar pumps are shipped with a check valve that must be installed prior to setting the
pump. These are used to protect the pump from water pressure driving it in the reverse direction,
which could generate potentially harmful voltage to the controller. Most check valves have an arrow
indicator displaying the direction of flow; make sure the arrow is facing opposite the pump. To
reduce the chances of this valve being installed improperly, it will ship with an all-thread adapter
already mounted. The all-thread will be connected to the pump outlet, whereas the drop pipe fittings
will attach to the other.