INSTRUCTIONS
NON-RETURN VALVES:
Non-return valves must be installed
if the air for your Sunshower is
extracted from a humid area, e.g.
from the outside or from the
bathroom. Please refer to the
image and subsequent pages for
instructions. The non-return valves
can be ordered additionally (as a
set with the glass panels) or can
be purchased separately at your
hardware store.
Examples of humid areas:
bathroom, outside.
Examples of dry areas:
bedroom, hallway, toilet.
GENERAL VENTILATION
GUIDELINES:
• All Sunshower appliances must
be installed with ventilation
ducts
• Ventilation feed and exhaust
can both be a maximum of 3 m
• The space from which/to which
ventilation is provided must be
at least 12 m
3
• The ducts can be of any
material, with dimensions Ø100
mm or 110 * 55 mm
• Make as few bends as possible
in the ducts
• The Sunshower may not be
connected to an existing
ventilation system
INSTALLATION MANUAL PURE | PART I | P1528 REV B