43
How to use the imbedded handy controller
[Note]
When modifying the sequence by using the handy controller, the change in the sequence number is not displayed, so more care
should be exercised in conducting the modification.
Use
and
buttons when changing the value of sequence.
Use
and
buttons to move to the next sequence.
Sequence
B-55
Group B
Program Start
+
⇨
⇨
⇨
80[ms]
Lapsed Time: Unit-1[ms]
T/T Sol. ON
Sequence Start
⇨
⇨
⇨
⇨
W/P Sol. ON
66[ms]
Lapsed Time: Unit-1[ms]
T/T Sol. OFF
⇨
⇨
⇨
⇨
0 [ms]
Sequence End
W/P Sol. OFF
Lapsed Time: Unit-1[ms]
⇨
⇨
⇨
⇨
Sequence Save