8.1) Adjustment of Thread Take-up Lever
Spring
1) Loosen the stopper tightening screw
①
as in the
figure and turn the thread take-up spring stopper
②
counterclockwise. Then the operating scope of the
thread take-up lever spring
③
becomes narrower.
Otherwise, the operating scope becomes wider.
※
The standard operating scope of the thread take-
up lever is 5~10mm.
2) Adjusting Tension of Thread Take-up Spring A
Loosen the thread tension adjusting device shaft nut
①
and fixation screw
⑤
, turn the groove of thread tension
adjusting device shaft
②
with driver in a clockwise direction to decrease the tension of thread take-up spring
③
and turn it counter-clockwise to increase the tension.
3) Adjusting Tension of Thread Take-up Spring B
Loosen the fixation screw
⑥
and turn the adjusting collar
⑦
in a clockwise direction to decrease the tension of
spring
④
and turn it counter-clockwise to increase the tension.
[Fig. 8-1]
•
For machine maintenance and repair, consult with qualified technicians.
•
For electrical maintenance and repair, consult with qualified technicians or agencies.
•
When safety devices are disassembled, make sure to return them to original positions.
•
Use both hands when bending the machine backwards or returning it to the original position. Using
only one hand can lead to severe hand injuries due to the weight of the machine.
•
Turn off the switch and pull the plug. Pressing pedal by mistake may result in physical injuries.
-
Inspection, maintenance, repair
-
Exchanging expendable parts such as needle, hook, knife.
-
Adjusting hook oil flow
•
In case you operate the machine when the power is on, please take special precaution.