1) Inserting the needle
As in figure 19, place the upper end of the needle closely
adhered to the upper side of the stopper hole
②
, with the
needle groove
①
facing inward. Fix the needle with a
fixing screw
③
.
2) Removing bobbin and bobbin case
Place the needle
①
in the highest position, and then just like in figure 20, open the slide plates
②
on the left and right, lift the
bobbin holder
③
to remove the bobbin case
④
and the bobbin
⑤
.
[Figure 19]
[Figure 20]
16
3
Adjustment of the machine
Caution
▶
In case of setting the needle, be sure to switch off the power supply. If the user presses on the
step by mistake, the machine will start automatically, and this might lead to physical injuries.
▶
When using the clutch motor, remember that the motor revolves for a while even after switching
off the power supply due to inertia. Make sure to start working only after the motor has come to
a complete stop.
Caution
▶
In case of adjusting the tension of the lower thread, be sure to switch off the power supply. If the
user presses on the step by mistake, the machine will start automatically, and this might lead to
physical injuries.
▶
When using the clutch motor, remember that the motor revolves for a while even after switching off
the power supply due to inertia. Make sure to start working only after the motor has come to a