23
12) Clearance adjustment between hook
and opener
Loosen the opener fastening screw
③
and adjust the opener
②
to the right and left so that the distance between the hook
①
and the opener
②
is 0.2mm when the opener
②
is pulled
to its max towards the arrowed direction. (See figure 38)
A. When stopping the left needle bar
Place the needle bar trimming direction lever
①
to the L (left) position.
B. When stopping the right needle bar
Place the needle bar trimming direction lever
①
to the R (right) position.
C. When switching to two needle sewing
Vertically press the needle bar return pressing plate
②
.
The needle bar trimming reverse lever
①
will return
automatically.
※
The needle bar trimming reverse lever
①
can be used
even during operation. However, don
’
t use this
function when the needle bar is in the highest position.
It works safely from the point when the needle bar is
about 3 mm below the highest point.
13) Operation of needle bar (left, right) stop (KM-790 series)
(1) Non-trimming type (KM-790, 790BL)
[Figure 38]
stop
stop