28
After adjusting the stitch length, fix it firmly by tightening the feed rocker link shaft screw
then fill the left screw
of the bed.
(The left screw
of the bed is to prevent oil leakage so tighten it firmly.)
After adjusting the needle guard(back)
to the proper position and tighten the needle guard(back) clamp screw
firmly.
9) DIFFERENTIAL FEED ADJUSTMENT
To adjust the differential feed dog, rotate the differential feed
operating lever
to the left or the right.
If the differential feed operating lever
is on the 4 or 5, the
momentums of the main feed dog and the differential feed dog
will be the same.
For the forward differential, turn the differential feed operating
lever
to the scale of 9. For the reverse differential, turn the
differential feed operating lever
to the scale of 1.