If you need to replace the burner assembly, loosen screws A and 
B,  unscrew  the  tubing  fittings  C,  and  disconnect  the  assembly, 
see Figure 5 

.

 

 

WARNING:

 FAILURE TO KEEP THE PRIMARY AIR 

OPENING(S) OF THE BURNER(S) CLEAN MAY RESULT IN SOOTING 
AND PROPERTY DAMAGE. 

WARNING:

:DO NOT ALLOW FANS TO BLOW DIRECTLY INTO 

THE  FIREPLACE.  AVOID  DRAFTS  THAT  ALTER  BURNER  FLAME 
PATTERNS.

  

 
OXYGEN DEPLETION SENSOR (ODS) SERVICING 

Dust and dirt may effect heater performance. 
This  heater  draws  air  into  the  bottom  of  it  during  normal 
operation.  In the process, dust and dirt will also be drawn 
into the heater.  The frequency of cleaning will depend on 
how  and  where  the  heater  is  used.    At  a  minimum,  you 
should  clean  the  heater  at  least  once  a  year,  at  the 
beginning of the heating season. 

 

If  your  pilot  will  not  stay  lit,  try  cleaning  it.    Use  a  can  of 
compressed  air,  such  as  is  used  to  clean  a  computer,  to 
blow  dust  out  of  the  pilot  assembly.    Sometimes  just 
blowing air back through the pilot will get rid of the dirt.  

 

If that fails to solve the problem, remove the wire clip that 

holds the metal strip onto the pilot assembly.  Remove the 
cover and blow  any dust out.  Reassemble and check for 
proper operation. 
If that fails, the pilot assembly should be removed and air 
blown  through  the  assembly  and  gas  line  as  shown  in 
Figure 6.  To prevent damage to this assembly, follow the 
instructions  below  for  disassembly  and  assembly  of  the 
ODS for cleaning.  

WARNING: 

 Never use needles, wires, 

or similar cylindrical objects to clean the pilot orifice.  This 
will only damage the calibrated ruby orifice (about the size 
of the head of a pin) which controls the pilot gas flow. 

 

 

Grab  Nut  A  with  an  open-end  wrench  and  loosen  Nut  B 
from the pilot tubing.  Blow air pressure through the holes 
as indicated in Figure 6.  This should blow out any foreign 
materials.  To reassemble, tighten Nut B by grabbing Nut A 
with  the  open-end  wrench.   

NOTE:

    When  the  heater  is 

reassembled, always check for gas leaks as outlined in the 
Gas Supply section of these instructions. 
 

WARNING: 

DO NOT USE A BLOWER INSERT, 

HEAT EXCHANGER INSERT OR OTHER 
ACCESSORY NOT APPROVED FOR USE WITH 
THIS HEATER. 

 
 

 

 

WARNING:  This vent-free heater is approved for use only with the type of gas indicated on the heater nameplate. 

Field  conversion  is  not  permitted.  Contact  our  Technical  Service  Department  at  (704)  372-3486  if  you  have  any 
problems. 

Summary of Contents for SC10M-1-LP

Page 1: ...ance CONSUMER Retain this manual for future reference This is an unvented gas fired heater It uses air oxygen from the room in which it is installed Provisions for adequate combustion and ventilation air must be provided Refer to the section titled Combustion and ventilation air requirement Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appl...

Page 2: ...000 ft because shutdown of the heater by the ODS system may occur due to reduced oxygen levels at these altitudes 5 This appliance is only for use with the type of gas indicated on the nameplate THIS APPLIANCE IS NOT CONVERTIBLE FOR USE WITH OTHER GASES Please check the gas type shown on the heater nameplate prior to hooking the heater to the gas supply 6 DO NOT install this heater in bathrooms Th...

Page 3: ...ut rating of all gas equipment in the space 18 This heater shall not be installed in a room or space unless the required volume of indoor combustion air is provided by the method described in the National Fuel Gas Code ANSI Z223 1 NFPA 54 the International Fuel Gas Code or applicable codes 19 WARNING If the area in which the heater may be operated does not meet the required volume for indoor combu...

Page 4: ..._ x 20 Btu hr ____________________ Btu hr STEP 3 Add the Btu hr inputs of all fuel burning appliances in this space NOTE DO NOT include Direct Vent gas appliances because these have sealed combustion systems that draw combustion air from outdoors Examples of appliances to consider include gas ranges gas water heaters gas logs kerosene heaters etc Proposed Vent Free Heater _________________________...

Page 5: ... odorant in escaped gas can adsorb or absorb onto or into walls masonry and other materials and fabrics in a room That will take some of the odorant out of the gas reducing its odor intensity LP Gas may stratify in a closed area and the odor intensity could vary at different levels Since it is heavier than air there may be more odor at lower levels Always be sensitive to the slightest gas odor If ...

Page 6: ... the heater the clearance from any combustible materials must be a minimum of 10 from the left 10 from the right 36 from the top and 2 from the bottom Never install the heater in front of any flammable object especially do not place curtains furniture clothing or other flammable objects less than 36 from the front of the heater FLOOR MOUNT INSTALLATION When using the optional legs for Models SC10M...

Page 7: ...according to the dimensions shown on the upper corner of Figure 2 1 3 Drill another 5 16 hole on the wall stud for the lower mounting point 4 Screw in the three 3 plastic expansion anchors furnished with the unit as shown in Figure 2 1 5 Screw in the furnished screws to the anchors for the upper mounting points and hang the heater on the screws as shown in Figure 2 1 6 Fasten the bottom of the hea...

Page 8: ...revent moisture and contaminants in the gas supply from entering the heater controls The drip leg should be readily accessible to permit cleaning or emptying A drip leg should not be located where the condensate is likely to freeze Failure to use a drip leg can result in operational difficulties in the heater GAS SUPPLY CHECK A union must be provided directly at the gas inlet to the heater A manua...

Page 9: ...to the pilot assembly Remove the cover and blow any dust out Reassemble and check for proper operation If that fails the pilot assembly should be removed and air blown through the assembly and gas line as shown in Figure 6 To prevent damage to this assembly follow the instructions below for disassembly and assembly of the ODS for cleaning WARNING Never use needles wires or similar cylindrical obje...

Page 10: ...til pilot is lit Setting OFF OFF 1 2 P Pilot Burner Setting P OFF 1 2 P Pilot Burner 6 Continue depressing control knob for 30 seconds after pilot is lit before releasing If knob does not pop up when released stop and inmediately call your service technician or gas supplier 7 Pilot should remain lit If the pilot will not stay lit after several tries turn the gas control knob to OFF and call your s...

Page 11: ...gas valve BURNER DOES NOT LIGHT Pilot stays lit Burner orifice clogged Burner orifices not correct size Extremely low inlet gas pressure Gas valve is defective Clean or replace orifices Replace with correct size Contact gas supplier Replace gas valve IMPROPER BURNER PATTERN Slight smoke or odor during initial operation Residues from manufacturing process or dust Problem will be eliminated after a ...

Page 12: ...ater so that the solid portion of the base is facing towards the front of the heater using four 4 No 10 x 1 screws provided 4 Attach a field supplied pipe elbow 3 8 NPT thread to the bottom of the heater for connection to the gas line as shown in the figure below and as instructed previously in these instructions WARNING This heater must be installed on a wall whenever it is installed in a bedroom...

Page 13: ...10M 1 LP Propane Gas SC10M 1 NG Natural Gas WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury ...

Page 14: ...LS SC10M 1 LP Propane Gas SC10M 1 NG Natural Gas WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury ...

Page 15: ... 43597080 43597080 Screw 4 43708030 43708030 Spacer Out 5 43597140 43597140 Screw 6 43584160 43584170 ODS System 7 43576100 43576110 Regulator 8 43597110 43597110 Screw 9 43590050 43590050 Connector 10 43596070 43596070 Control Valve 11 43585770 43585770 Tubing Regulator to Tap 12 43585790 43585790 Tubing Tap to First Setting 13 43585800 43585800 Tubing Tap to Second Setting 14 43585330 Tubing Tub...

Page 16: ...15 Manufactured for SUNSTAR HEATING PRODUCTS INC 306 West Tremont Avenue Charlotte NC 28203 4946 704 372 3486 ...

Reviews: