Electrode condition: Visually check that the electrode gap is maintained at 5mm (0.199
”) and that the tips of the
flame sensor and spark electrode are free from deposits. Clean off any deposits. Check that the electrode
ceramic is free from cracks. See Section 21.2)
•
Suspension system: Check that the suspension system is holding the heater level. Make sure that the heater is
hanging securely, look for any evidence where the heater may have been hit accidentally and tighten any loose
hanging points. Check that S hooks are closed. Check that there is no evidence of wear on the chain at the
connection to the heater and at the ceiling.
•
Main Burner and Orifice: Check the Main burner and orifice; remove any dirt or debris including spider webs.
•
Foreign Objects: Check and remove any foreign objects that are logged between the heat shield and the heater.
•
Ceramic Glass: Clean the glass from the inside and outside using a damp cloth. See also Section 21.1) for safe
removal of glass.
•
Burner Assembly: The burner assembly is not serviceable. The metal back may be cleaned with a damp cloth,
the ceramic and gaskets must not be disturbed.
•
IMPORTANT: DO NOT DIRECT AN AIR LINE AT THE CERAMIC PLAQUE SURFACE AS IT MAY DAMAGE THE CERAMIC
TILES OR DISLODGE THE HIGH TEMPERATURE GASKET MATERIAL FROM AROUND THE TILES.
•
Safety Labels: Replace safety and all other labels if they are no longer visible. See section 23.0) for replacements.
•
Wall Tag: Ensure a wall tag has been placed near the heater
’
s thermostat or in a conspicuous area near the
heater. Review the information for accuracy, replace if the information is no longer visible.