88
Function No. : 030
Function Name : Electric wiper operation time
Function No. : 031
Function Name : Electric wiper standby time
Function No. : 032
Function Name : Pneumatic wiper operation time
It is to set the time for the pneumatic wiper operation.
It is to set the time for the wiper operation. (Factory installed condition : “100ms”)
[Contents] When using the pneumatic wiper, set the time for its operation.
The higher the level, the longer the operation.
But when the level is too low, the wiper may not operate.
032. Air WP On Tm
0~1020ms
Setting
Value
It is to set the standby time for the electric wiper operation.
It is to set up the standby time until the next operation of the electric wiper.
(Factory installed condition : “100ms”)
[Contents] The interval until the next operation after the electric Wiper has operated.
The higher the level, the longer the interval between operations.
On the other hand, the wiper may not operate, if the level is too low
031. Elc WP Off Tm
0~1020ms
Setting
Value
It is to set the time for the electric wiper operation.
It is to set the time for the electric wiper operation. (Factory installed condition :”52ms”)
[Contents ] When using the electric wiper, set the time for operation.
The higher the level, the longer the operation.
The wiper may not operate when the time is set too short.
030. Elc WP On Tm
0~1020ms
Setting
Value
Function No. : 033
Function Name : Pneumatic wiper standby time
It is to set the standby time until the next operation of the pneumatic wiper.
It is to set the standby time until the next operation of the pneumatic wiper.
(Factory installed condition : “100ms”)
[Contents] The interval until the next operation when using the pneumatic wiper.
The higher the level, the longer the operation.
But if the level is too low, the wiper may not operate.
033. Air WP Off Tm
0~1020ms
Setting
Value