97
Function No. : 053
Function Name : Setting the magnifying/demagnifying mode
It is to select and set the magnifying /demagnifying mode.
The Magnifying /demagnifying function is not used.
[Contents] The machine uses the pattern data in the programmed size.
As the magnifying/demagnifying function is not selected, the X scale , Y scale
keys are not operated. Adjust the “XS”and “YS”indicated on the screen to
100%
053. Scale Mode
1) DISABLE
Setting
Value
It is to set the magnifying/demagnifying mode using the stitch length.
(Factory installed condition)
[Contents] While the number of stitches are the same, the length of the stitches along
the X and Y axis are adjusted according to the magnifying/demagnifying rate.
Set the rate within the feed plate transfer limit.
2) STITCH_LEN
It is to set the magnifying/demagnifying mode using the number of stitches.
[Contents] While the length of stitches are the same, the number of stitches are adjusted
along the X and Y axis. Set the rate within the feed plate transfer limit.
3) STITCH_NUM
Magnifying/demagnifying
according to stitch length
Magnifying/demagnifying
according to number of stitches