27
Function No. : 051
Function Name : Left feed plate full on time
Function No. : 052
Function Name : 2 step stroke full on time
Function No. : 053
Function Name : Inverting device full on time
It is to set the operation starting power of solenoid in left feed plate.
It is to set the time when the maximum current is permitted to solenoid.
(Factory installed condition : “200ms”)
[Contents] In case of using solenoid in left feed plate, the machine adjusts the time when
the maximum current is permitted to solenoid (Full on time) for setting the
power when relevant actuator starts operation.
051. FFLFull On Tm
100~1020ms
Setting
Value
It is to set the operation starting power of solenoid in 2step stroke.
It is to set the time when the maximum current is permitted to solenoid.
(Factory installed condition :“200ms”)
[Contents] In case of using solenoid in 2 step stroke, the machine adjusts the time
when the maximum current os permitted to solenoid (Full on time) for setting
power when relevant actuator starts operation.
052. TSFull On Tm
100~1020ms
Setting
Value
It is to set the operation starting power of solenoid in auxiliary output 2.
It is to set the time when the maximum current is permitted to solenoid.
(Factory installed condition : “200ms”)
[Contents] In case of using solenoid in auxiliary output 2, the machine adjusts the time
when the maximum current is permitted to solenoid (Full on time) for setting
power when relevant actuator starts operation.
053. RVFull On Tm
100~1020ms
Setting
Value